The clinical comparison of skeletal imaging agents
99-MTc-methylene diophosphonate from two manufacturers was compared with 99mTc-ethane hydroxy diphosphonate in a randomised trial to assess the relative blood clearances and the subsequent image quality. The 99mTc-methylene diphosphonate preparations were found to be superior with respect to both bl...
Gespeichert in:
Veröffentlicht in: | European Journal of Nuclear Medicine 1980-06, Vol.5 (3), p.257-260 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 99-MTc-methylene diophosphonate from two manufacturers was compared with 99mTc-ethane hydroxy diphosphonate in a randomised trial to assess the relative blood clearances and the subsequent image quality. The 99mTc-methylene diphosphonate preparations were found to be superior with respect to both blood clearance and subjectively assessed image quality, particularly when the interval between injection and scanning was three hours. Bone/soft tissue ratios did not mirror the highly significant qualitative comparisons of image quality. |
---|---|
ISSN: | 0340-6997 1619-7089 |