Image quality and radiopharmaceutical parameters of Indium-111 granulocytes in scintigraphy of inflammatory bowel disease

This study was undertaken to investigate the influence of various parameters of injected autologous 111In labelled granulocytes on scintigraphic image quality. Forty-two scintigrams of 37 patients with inflammatory bowel disease were evaluated. The images were divided into three groups according to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European Journal of Nuclear Medicine 1989-04, Vol.15 (4), p.197-200
Hauptverfasser: ARNDT, J. W, CRAMA-BOHBOUTH, G. E, VERSPAGET, H. W, BLOK, D, PENA, A. S, THAM, R. T. O. T. A, WETERMAN, I. T, LAMERS, C. B. H. W, PAUWELS, E. K. J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study was undertaken to investigate the influence of various parameters of injected autologous 111In labelled granulocytes on scintigraphic image quality. Forty-two scintigrams of 37 patients with inflammatory bowel disease were evaluated. The images were divided into three groups according to quality: good, intermediate and poor. The relationships between image quality and such radiopharmaceutical parameters as injected dose of 111In, number of injected cells and specific activity were investigated. It appeared that in order to obtain interpretable images, a specific activity of at least 85 kBq 111In/million cells was necessary. The activity of the injected dose must exceed 7 MBq if poor quality images and very long acquisition times are to be avoided.
ISSN:0340-6997
1619-7089
DOI:10.1007/bf00253794