The radiation dose to surgical personnel during intraoperative radioimmunoscintimetry
To estimate the radiation exposure to surgical personnel caused by intraoperative radioimmunoscintimetry, we measured dose rates at different distances from patients who had been injected with 950 MBq technetium-99m-labelled intact carcinoembryonic antigen (CEA)-specific antibodies (Szintimun CEA, B...
Gespeichert in:
Veröffentlicht in: | European Journal of Nuclear Medicine 1992-02, Vol.19 (2), p.110-112 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To estimate the radiation exposure to surgical personnel caused by intraoperative radioimmunoscintimetry, we measured dose rates at different distances from patients who had been injected with 950 MBq technetium-99m-labelled intact carcinoembryonic antigen (CEA)-specific antibodies (Szintimun CEA, Behring AG Marburg, FRG) for immunoscintigraphy 24 h earlier. At 0.05 m (corresponding to working positions during surgery) we found 2.0-16.0 microSv h-1 (average 6.4), which is similar to results for nuclear medicine staff. Thus, if radioimmunoscintimetry is to become a routine procedure, according to national regulations in some countries of the European Communities surgical personnel might be regarded as professionally exposed to radiation. |
---|---|
ISSN: | 0340-6997 1619-7089 |
DOI: | 10.1007/bf00184125 |