A simple scintigraphic method for continuous monitoring of gastric emptying
A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s a...
Gespeichert in:
Veröffentlicht in: | European Journal of Nuclear Medicine 1993-03, Vol.20 (3), p.260-263 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as activity retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. |
---|---|
ISSN: | 0340-6997 1619-7089 |
DOI: | 10.1007/BF00170009 |