Safety margin at single neuromuscular junctions

Jitter measurement with axonal microstimulation was used to study synaptic function at 115 neuromuscular junctions (NMJs) of normal subjects at various stimulation rates. Jitter was lowest at 0.5 Hz; it increased slightly at 1, 2, and 5 Hz and remained at that level at 10 Hz (a light work load) and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Muscle & nerve 2002, Vol.25 (S11), p.S21-S27
Hauptverfasser: Trontelj, Jože V., Mihelin, Marjan, Khuraibet, Adnan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Jitter measurement with axonal microstimulation was used to study synaptic function at 115 neuromuscular junctions (NMJs) of normal subjects at various stimulation rates. Jitter was lowest at 0.5 Hz; it increased slightly at 1, 2, and 5 Hz and remained at that level at 10 Hz (a light work load) and 20 Hz (a heavy work load); and it increased further at 50 Hz (an extreme load). This pattern was seen for the majority of the NMJs, suggesting a high safety factor of neuromuscular transmission maintained rather uniformly over a wide range of discharge rates. A proportion of the normal NMJs had relatively large jitter; these tended to show prominent facilitation as the rate was raised from 5 or 10 to 20 Hz. Similar but more dramatic facilitation improving the safety factor was seen at most NMJs in myasthenia, which was studied for comparison. Such facilitation was not found at normal NMJs with low jitter. © 2002 Wiley Periodicals, Inc. Muscle Nerve Supplement 11: S21–S27, 2002
ISSN:0148-639X
1097-4598
DOI:10.1002/mus.10143