Randomized, double-blind, phase III clinical study of a novel nanotechnological topical anesthetic formulation containing lidocaine 25 mg/g and prilocaine 25 mg/g (nanorap) in skin phototypes I-III patients with ablative fractional CO 2 laser treatment indication in the forehead

Nanotechnology may increase the speed of penetration into the skin. This study evaluated the efficacy, safety, and pharmacokinetics of a novel topical anesthetic nanocapsule formulation (2 g) containing 2.5% lidocaine and 2.5% prilocaine (nanorap-test formulation) compared to placebo (control formul...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lasers in surgery and medicine 2019-09, Vol.51 (7), p.609-615
Hauptverfasser: Gobbato, Cíntia, Gobbato, André, Magalhães, Tainah B, Mendes, Gustavo D, Ilha, Jaime O, Moreno, Ronilson A, Antunes, Natalícia J, De Nucci, Gilberto
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nanotechnology may increase the speed of penetration into the skin. This study evaluated the efficacy, safety, and pharmacokinetics of a novel topical anesthetic nanocapsule formulation (2 g) containing 2.5% lidocaine and 2.5% prilocaine (nanorap-test formulation) compared to placebo (control formulation) in skin types I-III patients of both sexes submitted to the ablative fractional CO laser treatment. The patients (n = 120) included in this double-blind, single-center, randomized trial, received topical application of 2 g of the test formulation (50 mg lidocaine + 50 mg prilocaine) and placebo on the forehead region. Efficacy was assessed as pain sensation in four quadrants of each side of the forehead using a visual analogue scale immediately (0 min) and at 30, 60, and 90 minutes after laser application compared to placebo. The safety and tolerability of the test product were evaluated based on the occurrence of systemic adverse events as well as the occurrence of immediate and late skin reactions. Pharmacokinetic evaluation was performed in plasma of eight patients using a validated LC-MS/MS method for drugs quantification. Nanorap induced a clinically significant reduction in the pain assessment at all evaluated times (57.2%, 41.6%, 38.6%, and 37.3% at 0, 30, 60, and 90 minutes after drug application, respectively. Mean values of C were 14.20 and 5.36 ng/ml and t were 3.5 and 1.8 hour for lidocaine and prilocaine, respectively. No systemic adverse events were observed. The nanorap formulation demonstrated a clinically and statistically significant efficacy providing analgesia after the ablative fractional CO laser therapy in the investigated patients, when compared to placebo. The product also presented good safety and tolerability. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.
ISSN:0196-8092
1096-9101
DOI:10.1002/lsm.23071