Biexponential T 1ρ relaxation mapping of human knee menisci

Measuring T in the knee menisci can potentially be used as noninvasive biomarkers in detecting early-stage osteoarthritis (OA). To demonstrate the feasibility of biexponential T relaxation mapping of human knee menisci. Prospective. Eight healthy volunteers with no known inflammation, trauma, or pai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2019-09, Vol.50 (3), p.824-835
Hauptverfasser: Baboli, Rahman, Sharafi, Azadeh, Chang, Gregory, Regatte, Ravinder R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Measuring T in the knee menisci can potentially be used as noninvasive biomarkers in detecting early-stage osteoarthritis (OA). To demonstrate the feasibility of biexponential T relaxation mapping of human knee menisci. Prospective. Eight healthy volunteers with no known inflammation, trauma, or pain in the knee and three symptomatic subjects with early knee OA. Customized Turbo-FLASH sequence to acquire 3D-T -weighted images on a 3 T MRI scanner. T relaxation values were assessed in 11 meniscal regions of interest (ROIs) using monoexponential and biexponential models. Nonparametric rank-sum tests, Kruskal-Wallis test, and coefficient of variation. The mean monoexponential T relaxation in the lateral menisci were 28.05 ± 4.2 msec and 37.06 ± 10.64 msec for healthy subjects and early knee OA patients, respectively, while the short and long components were 8.07 ± 0.5 msec and 72.35 ± 3.2 msec for healthy subjects and 2.63 ± 2.99 msec and 55.27 ± 24.76 msec for early knee OA patients, respectively. The mean monoexponential T relaxation in the medial menisci were 34.30 ± 3.8 msec and 37.26 ± 11.38 msec for healthy and OA patients, respectively, while the short and long components were 7.76 ± 0.7 msec and 72.19 ± 4.2 msec for healthy subjects and 3.06 ± 3.24 msec and 55.27 ± 24.59 msec for OA patients, respectively. Statistically significant (P ≤ 0.05) differences were observed in the monoexponential relaxation between some of the ROIs. The T was significantly lower (P = 0.02) in the patients than controls. The rmsCV% ranges were 1.51-16.6%, 3.59-14.3%, and 4.91-15.6% for T -mono, T -short, and T -long, respectively. Our results showed that in all ROIs, T relaxation times of outer zones (red zones) were less than inner zones (white zones). Monoexponential T was increased in medial, lateral, and body menisci of early OA while the biexponential numbers were decreased in early OA patients. 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2019;50:824-835.
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.26631