Determination of the sulfur components of gasoline streams by capillary column gas chromatography with sulfur chemiluminescence detection
A method using a sulfur chemiluminescence detector (SCD) has been developed for the qualitative and quantitative determination of sulfur components in stabilized gasoline‐range process streams, including blended gasolines containing between 1 and > 4000 ppm total sulfur. The detection limit per s...
Gespeichert in:
Veröffentlicht in: | Journal of high resolution chromatography 1994-04, Vol.17 (4), p.255-258 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method using a sulfur chemiluminescence detector (SCD) has been developed for the qualitative and quantitative determination of sulfur components in stabilized gasoline‐range process streams, including blended gasolines containing between 1 and > 4000 ppm total sulfur. The detection limit per sulfur component was approximately 50 ppb. On‐column injection was employed for optimum precision and accuracy. A new probe material was found which did not soften under FID operating conditions. A new method, using a hydrogen sulfide permeation tube, was developed for rapid alignment of the probe in the FID. |
---|---|