Ternary data for the acetic acid-water-mesityl oxide system

The ternary equilibrium data for the system acetic acid‐mesityl oxide‐water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more tha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chemical technology and biotechnology. Chemical technology 1983-04, Vol.33 (3), p.145-150
Hauptverfasser: Hegazi, Mohamed F., Salem, Abu-Bakr
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 150
container_issue 3
container_start_page 145
container_title Journal of chemical technology and biotechnology. Chemical technology
container_volume 33
creator Hegazi, Mohamed F.
Salem, Abu-Bakr
description The ternary equilibrium data for the system acetic acid‐mesityl oxide‐water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more than 40 %. The tie line data were also determined. These data proved that mesityl oxide particularly in presence of salt is a promising solvent for acetic acid extraction from aqueous solutions.
doi_str_mv 10.1002/jctb.504330306
format Article
fullrecord <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_jctb_504330306</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_7C8XBDFX_S</sourcerecordid><originalsourceid>FETCH-LOGICAL-c275t-232763a1ffeb81165d5c4b1999bddd2c83b631d8241840aaeb128aa5eb22d49d3</originalsourceid><addsrcrecordid>eNo9j01PAjEURRujiYhuXc8fKPb1tZ1OXCkKmhBdiJFd06-JgyCmbSL8e4dgWJ3NvTf3EHINbASM8ZulL24kmUBkyNQJGUCDkoJGdUoGjCtBUQCek4ucl4yhwJoNyO08pm-bdlWwxVbtJlXlM1bWx9L5Hl2gv7bERNcxd2W3qjbbLsQq73KJ60ty1tpVjlf_HJL3yeN8_ERnr9Pn8d2Mel7LQjnyWqGFto1OAygZpBcOmqZxIQTuNTqFEDQXoAWzNjrg2loZHedBNAGHZHTY9WmTc4qt-Unduj9tgJm9utmrm6N6X6CHQtff3B7TNn0ZVWMtzcfL1NRjvbh_mCzMG_4BYXhb1A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Ternary data for the acetic acid-water-mesityl oxide system</title><source>Access via Wiley Online Library</source><creator>Hegazi, Mohamed F. ; Salem, Abu-Bakr</creator><creatorcontrib>Hegazi, Mohamed F. ; Salem, Abu-Bakr</creatorcontrib><description>The ternary equilibrium data for the system acetic acid‐mesityl oxide‐water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more than 40 %. The tie line data were also determined. These data proved that mesityl oxide particularly in presence of salt is a promising solvent for acetic acid extraction from aqueous solutions.</description><identifier>ISSN: 0264-3413</identifier><identifier>EISSN: 1935-1836</identifier><identifier>DOI: 10.1002/jctb.504330306</identifier><language>eng</language><publisher>London: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Acetic acid-mesityl oxide-water system ; acid extraction ; solubility ; ternary equilibrium data ; tie line data</subject><ispartof>Journal of chemical technology and biotechnology. Chemical technology, 1983-04, Vol.33 (3), p.145-150</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c275t-232763a1ffeb81165d5c4b1999bddd2c83b631d8241840aaeb128aa5eb22d49d3</citedby><cites>FETCH-LOGICAL-c275t-232763a1ffeb81165d5c4b1999bddd2c83b631d8241840aaeb128aa5eb22d49d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Hegazi, Mohamed F.</creatorcontrib><creatorcontrib>Salem, Abu-Bakr</creatorcontrib><title>Ternary data for the acetic acid-water-mesityl oxide system</title><title>Journal of chemical technology and biotechnology. Chemical technology</title><addtitle>J. Chem. Tech. Biotechnol</addtitle><description>The ternary equilibrium data for the system acetic acid‐mesityl oxide‐water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more than 40 %. The tie line data were also determined. These data proved that mesityl oxide particularly in presence of salt is a promising solvent for acetic acid extraction from aqueous solutions.</description><subject>Acetic acid-mesityl oxide-water system</subject><subject>acid extraction</subject><subject>solubility</subject><subject>ternary equilibrium data</subject><subject>tie line data</subject><issn>0264-3413</issn><issn>1935-1836</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1983</creationdate><recordtype>article</recordtype><recordid>eNo9j01PAjEURRujiYhuXc8fKPb1tZ1OXCkKmhBdiJFd06-JgyCmbSL8e4dgWJ3NvTf3EHINbASM8ZulL24kmUBkyNQJGUCDkoJGdUoGjCtBUQCek4ucl4yhwJoNyO08pm-bdlWwxVbtJlXlM1bWx9L5Hl2gv7bERNcxd2W3qjbbLsQq73KJ60ty1tpVjlf_HJL3yeN8_ERnr9Pn8d2Mel7LQjnyWqGFto1OAygZpBcOmqZxIQTuNTqFEDQXoAWzNjrg2loZHedBNAGHZHTY9WmTc4qt-Unduj9tgJm9utmrm6N6X6CHQtff3B7TNn0ZVWMtzcfL1NRjvbh_mCzMG_4BYXhb1A</recordid><startdate>198304</startdate><enddate>198304</enddate><creator>Hegazi, Mohamed F.</creator><creator>Salem, Abu-Bakr</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>198304</creationdate><title>Ternary data for the acetic acid-water-mesityl oxide system</title><author>Hegazi, Mohamed F. ; Salem, Abu-Bakr</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c275t-232763a1ffeb81165d5c4b1999bddd2c83b631d8241840aaeb128aa5eb22d49d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1983</creationdate><topic>Acetic acid-mesityl oxide-water system</topic><topic>acid extraction</topic><topic>solubility</topic><topic>ternary equilibrium data</topic><topic>tie line data</topic><toplevel>online_resources</toplevel><creatorcontrib>Hegazi, Mohamed F.</creatorcontrib><creatorcontrib>Salem, Abu-Bakr</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Journal of chemical technology and biotechnology. Chemical technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hegazi, Mohamed F.</au><au>Salem, Abu-Bakr</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ternary data for the acetic acid-water-mesityl oxide system</atitle><jtitle>Journal of chemical technology and biotechnology. Chemical technology</jtitle><addtitle>J. Chem. Tech. Biotechnol</addtitle><date>1983-04</date><risdate>1983</risdate><volume>33</volume><issue>3</issue><spage>145</spage><epage>150</epage><pages>145-150</pages><issn>0264-3413</issn><eissn>1935-1836</eissn><abstract>The ternary equilibrium data for the system acetic acid‐mesityl oxide‐water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more than 40 %. The tie line data were also determined. These data proved that mesityl oxide particularly in presence of salt is a promising solvent for acetic acid extraction from aqueous solutions.</abstract><cop>London</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/jctb.504330306</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0264-3413
ispartof Journal of chemical technology and biotechnology. Chemical technology, 1983-04, Vol.33 (3), p.145-150
issn 0264-3413
1935-1836
language eng
recordid cdi_crossref_primary_10_1002_jctb_504330306
source Access via Wiley Online Library
subjects Acetic acid-mesityl oxide-water system
acid extraction
solubility
ternary equilibrium data
tie line data
title Ternary data for the acetic acid-water-mesityl oxide system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T01%3A12%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ternary%20data%20for%20the%20acetic%20acid-water-mesityl%20oxide%20system&rft.jtitle=Journal%20of%20chemical%20technology%20and%20biotechnology.%20Chemical%20technology&rft.au=Hegazi,%20Mohamed%20F.&rft.date=1983-04&rft.volume=33&rft.issue=3&rft.spage=145&rft.epage=150&rft.pages=145-150&rft.issn=0264-3413&rft.eissn=1935-1836&rft_id=info:doi/10.1002/jctb.504330306&rft_dat=%3Cistex_cross%3Eark_67375_WNG_7C8XBDFX_S%3C/istex_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true