Biochemical features of pseudomembrane at the bone-cement interface of loosened total hip prostheses

Biochemical features of pseudomembrane formed at the bone‐cement interface of 13 failed total hip replacements were studied and histological examination of the pseudomembrane was conducted. The results of biochemical analyses revealed on average hydroxyproline, 86 μg/mg; water content, 57%; hexosami...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical materials research 1983-07, Vol.17 (4), p.669-678
Hauptverfasser: Shoji, Hiromu, Karube, Shunji, D'ambrosia, Robert D., Dabezies, Eugene J., Miller, Douglas R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Biochemical features of pseudomembrane formed at the bone‐cement interface of 13 failed total hip replacements were studied and histological examination of the pseudomembrane was conducted. The results of biochemical analyses revealed on average hydroxyproline, 86 μg/mg; water content, 57%; hexosamine, 12 μg/mg; glucosamine/galactosamine, 1.4%; and calcium, 2.1%. Approximately 78% of collagen was extracted with pepsin, whereas only 8 and 0.3% collagen were extracted with acetic acid and neutral salt, respectively. On further differential salting out of the extracted collagen, about 77% was type I collagen, 19% type III, and 2.6% type V. Unlike pseudoarthrosis of fracture, no type II collagen was identified. Overall biochemical features in the light of the histological appearance suggested that pseudomembrane resembles granulation tissue. Bone healing mechanisms at the bone‐cement interface appear to differ from that of fracture healing.
ISSN:0021-9304
1097-4636