Simultaneous determination of mitotane, its metabolite, and five steroid hormones in urine samples by capillary electrophoresis using β-CD 2 SDS 1 complexes as hydrophobic compounds solubilizers

Mitotane is a cytotoxic drug used in the treatment of inoperable adrenocortical carcinoma, it inhibits steroidogenesis as well, and therefore monitoring the level of steroid hormones in patients treated with mitotane is a crucial point of therapy. Hence, we have developed a simple, fast, and efficie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrophoresis 2022-05, Vol.43 (9-10), p.990-997
Hauptverfasser: Pieckowski, Michał, Kowalski, Piotr, Olędzka, Ilona, Miękus-Purwin, Natalia, Plenis, Alina, Roszkowska, Anna, Bączek, Tomasz
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Mitotane is a cytotoxic drug used in the treatment of inoperable adrenocortical carcinoma, it inhibits steroidogenesis as well, and therefore monitoring the level of steroid hormones in patients treated with mitotane is a crucial point of therapy. Hence, we have developed a simple, fast, and efficient electrophoretic method combined with reverse polarity sweeping as online preconcentration technique and dispersive liquid-liquid microextraction for the simultaneous determination of mitotane, its main metabolite DDA, and five steroid hormones (progesterone, testosterone, epitestosterone, cortisol, and corticosterone) in urine samples. In addition, a new sample matrix consisting of β-CD SDS complexes for a high hydrophobic compounds solubilization was developed. Approach based on the application of β-cyclodextrin and SDS complex of a ratio 2:1 allowed for hydrodynamic injection into the capillary of a solution containing both mitotane and other analytes. The detection limits of the analytes for the reverse polarity sweeping-dispersive liquid-liquid microextraction method were found to be in the range of 1.5-3 ng/mL, which were approximately 1000 times lower than in the conventional hydrodynamic injection (5 s, 0.5 psi) without any preconcentration procedure. All analytes were completely resolved in less than 13 min by uncoated silica capillary with an inner diameter of 75 μm (ID) × 60 cm. Electrophoretic separation was performed in reverse polarity with a voltage of -25 kV with a background electrolyte (BGE) consisting of 100 mM SDS, 25% ACN, 25 mM phosphate buffer (pH 2.5), and 7 mM β-cyclodextrin.
ISSN:0173-0835
1522-2683
DOI:10.1002/elps.202100250