Alternating Current Tensammetry of Tetraphenylborate (TPB) and its Application for Potassium Determination

Alternating‐current polarography of tetraphenylborate ion (TPB) in acetate buffer (pH 4 to 5) or 0.1 to 0.5 M NaCl produces a characteristic tensammetric (pseudocapacitive) peak at −0.95 V (vs. SCE). Within a limited range (till about 0.2 mM), the tensammetric peak current is proportional to the TPB...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electroanalysis (New York, N.Y.) N.Y.), 2003-09, Vol.15 (17), p.1415-1418
Hauptverfasser: Ion, Ana, Costache, Madalina Beatrice, Grecu, I. V., Banica, F. G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Alternating‐current polarography of tetraphenylborate ion (TPB) in acetate buffer (pH 4 to 5) or 0.1 to 0.5 M NaCl produces a characteristic tensammetric (pseudocapacitive) peak at −0.95 V (vs. SCE). Within a limited range (till about 0.2 mM), the tensammetric peak current is proportional to the TPB concentration but it levels off at higher concentration. TPB concentration can also be determined within 5 to 50 μM by measuring the capacity current at −0.4 V or the differential pulse polarographic peak current at −0.85 V. The tensammetric peak current was used to determine the solubility of potassium tetraphenylborate in acetate buffer and sodium chloride solutions. Also, a method for amperometric back‐titration of potassium ion was worked out and applied to the analysis of mineral water.
ISSN:1040-0397
1521-4109
DOI:10.1002/elan.200302733