Continuous Matrix-assisted Refolding of Inclusion-body Proteins: Effect of Recycling

A recombinant therapeutic protein expressed in Escherichia coli in form of inclusion bodies was used as a model system for comparative studies on the refolding efficiencies obtained by continuous matrix‐assisted refolding or batch‐dilution in a stirred tank reactor. Due to the strong aggregation ten...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering & technology 2005-11, Vol.28 (11), p.1375-1386
Hauptverfasser: Schlegl, R., Necina, R., Jungbauer, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A recombinant therapeutic protein expressed in Escherichia coli in form of inclusion bodies was used as a model system for comparative studies on the refolding efficiencies obtained by continuous matrix‐assisted refolding or batch‐dilution in a stirred tank reactor. Due to the strong aggregation tendency the refolding yield after dilution into an appropriate renaturation buffer was only 10 % at a protein concentration of 0.1 mg/mL. To improve the yield of active protein matrix‐assisted refolding using size‐exclusion chromatography was tested. A preparative continuous annular chromatography system (PCAC) equipped with a size‐exclusion resin was used for continuous processing of the solubilized unfolded protein. As the protein passed through the column, it was separated from the chaotropic agent and started to regain its native structure. Tightly bound aggregates produced during the refolding reaction were continuously removed from the rotating bed by 6 M guanidine‐hydrochloride. The aggregate fraction was recycled to the feed stream after concentrating by ultradiafiltration to increase the amount of refolded protein. The refolding yield of 27 % without recycling was increased to 45 % at a recycling rate of 0.51 at a protein concentration of 1 mg/mL. The stability of the reactor under continuous operation was shown for 15 hours without any significant loss of refolding efficiency or chromatographic resolution. Interdependencies of operational parameters such as protein concentration, loading factor and recycling rate on throughput of refolded protein are shown. The recovery of a recombinant therapeutic protein expressed as an inclusion body in Escherichia coli succeeds the application of continuous refolding in a preparative continuous annular chromatography system (PCAC) equipped with a size exclusion resin. The efficiency of the refolding reactor was increased by recycling the aggregated protein fraction.
ISSN:0930-7516
1521-4125
DOI:10.1002/ceat.200500121