Effects of GSM-900 microwaves on the experimental allergic encephalomyelitis (EAE) rat model of multiple sclerosis

The effects of acute exposure to GSM‐900 microwaves (900 MHz, 217 Hz pulse modulation) on the clinical parameters of the acute experimental allergic encephalomyelitis (EAE) model in rats were investigated in two independent experiments: rats were either habituated or nonhabituated to the exposure re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bioelectromagnetics 2003-04, Vol.24 (3), p.211-213
Hauptverfasser: Anane, R., Geffard, M., Taxile, M., Bodet, D., Billaudel, B., Dulou, P.E., Veyret, B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effects of acute exposure to GSM‐900 microwaves (900 MHz, 217 Hz pulse modulation) on the clinical parameters of the acute experimental allergic encephalomyelitis (EAE) model in rats were investigated in two independent experiments: rats were either habituated or nonhabituated to the exposure restrainers. EAE was induced with a mixture of myelin basic protein and Mycobacterium tuberculosis. Female Lewis rats were divided into cage control, sham exposed, and two groups exposed either at 1.5 or 6.0 W/kg local specific absorption rate (SAR averaged over the brain) using a loop antenna placed over their heads. There was no effect of a 21 day exposure (2 h/day) on the onset, duration, and termination of the EAE crisis. Bioelectromagnetics 24:211–213, 2003. © 2003 Wiley‐Liss, Inc.
ISSN:0197-8462
1521-186X
DOI:10.1002/bem.10093