Heat transfer in liquid-liquid spray towers
An experimental investigation of heat transfer rates in which were used three spray towers varying from 4 to 6 in. in diameter and 7 to 10 ft. in height, and distributor elements with hole sizes varying from 1/8 to 1/64 in. in diameter was carried out. The immiscible liquid system consisted of water...
Gespeichert in:
Veröffentlicht in: | AIChE journal 1967-11, Vol.13 (6), p.1160-1166 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An experimental investigation of heat transfer rates in which were used three spray towers varying from 4 to 6 in. in diameter and 7 to 10 ft. in height, and distributor elements with hole sizes varying from 1/8 to 1/64 in. in diameter was carried out. The immiscible liquid system consisted of water and kerosene (normal boiling point range 395° to 490°F.). Volumetric heat transfer coefficients ranged from 100 to 3,600 B.t.u./(hr.)(cu. ft.)(°F.) and the overall film heat transfer coefficients ranged from 4 to 23 B.t.u./(hr.)(sq. ft.)(°F.). Height equivalent to a theoretical stage varied from 1 to 8 ft. Scale‐up correlations relating these rate data to operating variables were developed. |
---|---|
ISSN: | 0001-1541 1547-5905 |
DOI: | 10.1002/aic.690130623 |