Noncontact High-Resolution Ultra–Wide-Field Oral Fluorescein Angiography in Premature Infants With Retinopathy of Prematurity
IMPORTANCE We report for the first time, to our knowledge, the acquisition of noncontact ultra–wide-field oral fluorescein angiograms in premature infants with retinopathy of prematurity. OBSERVATIONS High-resolution oral fluorescein angiograms were successfully obtained in 3 consecutive premature i...
Gespeichert in:
Veröffentlicht in: | JAMA ophthalmology 2014-01, Vol.132 (1), p.108 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | IMPORTANCE We report for the first time, to our knowledge, the acquisition of noncontact ultra–wide-field oral fluorescein angiograms in premature infants with retinopathy of prematurity. OBSERVATIONS High-resolution oral fluorescein angiograms were successfully obtained in 3 consecutive premature infants with retinopathy of prematurity at the Oxford Eye Hospital, Oxford, England, using the Optos Panoramic 200MA imaging system (Optos PLC). CONCLUSIONS AND RELEVANCE Noncontact ultra–wide-field oral fluorescein angiograms captured using the Optos Panoramic 200MA fluorescein angiographic system provide a safe and alternative method for evaluating the retinal vasculature in premature infants with retinopathy of prematurity. |
---|---|
ISSN: | 2168-6165 2168-6173 |