A New Apparatus for Measuring the Principal Strains in Anisotropic Clays
An apparatus and an experimental arrangement were developed to provide an accurate measurement of the lateral deformation of soft sensitive clays. The apparatus contained light gage points and displacement transducers floated in a cell fluid in such a way that internal strains could be measured dire...
Gespeichert in:
Veröffentlicht in: | Geotechnical testing journal 1978-03, Vol.1 (1), p.24-33, Article 24 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An apparatus and an experimental arrangement were developed to provide an accurate measurement of the lateral deformation of soft sensitive clays. The apparatus contained light gage points and displacement transducers floated in a cell fluid in such a way that internal strains could be measured directly on the soil specimen with the least amount of disturbance. The performance data obtained from the testing of a soft sensitive clay indicated that the apparatus developed possessed adequate precision and stability for the study of the deformation behavior of clays. |
---|---|
ISSN: | 0149-6115 1945-7545 |
DOI: | 10.1520/GTJ10365J |