Rapid ultrasonic C-scan on image test for spot welding based interpolation
In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan image generated cannot be used to assess spot welding quality reliably. Based on bicubi...
Gespeichert in:
Veröffentlicht in: | 中国焊接:英文版 2014 (4), p.37-43 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan image generated cannot be used to assess spot welding quality reliably. Based on bicubic image interpolation, the C-scan image in low resolution with the large step length 1 000 ~xm is subdivided and reconstructed. By this means, the C-scan image resolution is greatly enhanced and testing results obtained are satisfactory, realizing rapid assessment of spot welds. The results of rapid ultrasonic C-scan test fit the actual metallographic measured value well. Mean value of normal distribution of error statistics is O. 006 67, and the standard deviation is O. 087 11. Rapid ultrasonic C-scan test based on image interpolation is of high accuracy and excellent stability. |
---|---|