Diffusion-weighted MR imaging of normal and abnorma scrotum: preliminary results

Magnetic resonance (MR) imaging of the scrotum represents an important supplemental diagnostic tool in the evaluation of scrotal diseases. Diffusion-weighted (DW) MR imaging is a developing technique, proved to improve tissue characterization. We evaluated the feasibility and diagnostic performance...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:亚洲男性学杂志:英文版 2012, Vol.14 (4), p.649-654
1. Verfasser: Athina C Tsili Maria I Argyropoulou Dimitrios Giannakis Stavros Tsampalas Nikolaos Sofikitis Konstantinos Tsampoulas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Magnetic resonance (MR) imaging of the scrotum represents an important supplemental diagnostic tool in the evaluation of scrotal diseases. Diffusion-weighted (DW) MR imaging is a developing technique, proved to improve tissue characterization. We evaluated the feasibility and diagnostic performance of DW MR imaging in the detection and characterization of scrotal lesions. We retrospectively evaluated 31 scrotal lesions (23 intratesticular and 8 extratesticular) in 26 men. All MR examinations were performed on a 1.5-T unit, using a pelvic-phased array coil. DW sequences were obtained using a single shot, multislice spin echo planar diffusion pulse sequence and a b factor of 0 and 900 s mm-2. The DW MR characteristics and the apparent diffusion coefficient (ADC) values of normal scrotal contents and scrotal diseases were evaluated. Comparison between the ADC values of normal scrotum, benign lesions and scrotal malignancies was performed. The accuracy of conventional sequences, DW images alone and DW imaging combined with conventional images in differentiating benign from malignant scmtal lesions was calculated. The ADC values of testicular malignancies were different from those of normal testis and benign intratesticular lesions, and the ADC values of benign extratesticular lesions from those of normal epididymis (P〈0.05). The overall accuracy of conventional imaging, DW imaging alone and DW MR combined with conventional sequences in the characterization of intratesticular lesions was 91%, 87% and 100%, respectively. Our findings suggest that DW MR imaging and ADC values may provide valuable information in the diagnosis and characterization of scrotal diseases.
ISSN:1008-682X
1745-7262