Thermal analysis of DTL in the SSC-LINAC
A linear accelerator as a new injector for the Separated Sector Cyclotron at the Heavy Ion Research Facility of LAN Zhou is being designed. The Drift-Tube-Linac (DTL) has been designed to accelerate ^238U^34+ from 0.140 MeV/u to 0.97 MeV/u [1]. The 3D finite element analysis of thermal behavior is p...
Gespeichert in:
Veröffentlicht in: | Chinese physics C 2011-10, Vol.35 (10), p.952-954 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A linear accelerator as a new injector for the Separated Sector Cyclotron at the Heavy Ion Research Facility of LAN Zhou is being designed. The Drift-Tube-Linac (DTL) has been designed to accelerate ^238U^34+ from 0.140 MeV/u to 0.97 MeV/u [1]. The 3D finite element analysis of thermal behavior is presented in this paper. During operation, the cavity will produce Joule heat. The cavity will not work normally due to the high temperature and thermal deformation will lead to frequency drift, So it is necessary to perform thermal analysis to ensure the correct working temperature is used. The result of the analysis shows that after the water cooling system is put into the cavity the temperature rise is about 20 degrees and the frequency drift is about 0.15%. |
---|---|
ISSN: | 1674-1137 0254-3052 2058-6132 |
DOI: | 10.1088/1674-1137/35/10/012 |