Thermal analysis of DTL in the SSC-LINAC

A linear accelerator as a new injector for the Separated Sector Cyclotron at the Heavy Ion Research Facility of LAN Zhou is being designed. The Drift-Tube-Linac (DTL) has been designed to accelerate ^238U^34+ from 0.140 MeV/u to 0.97 MeV/u [1]. The 3D finite element analysis of thermal behavior is p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics C 2011-10, Vol.35 (10), p.952-954
1. Verfasser: 吴锡 袁平 何源 马力祯 张小奇 吴巍 杨雅青
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A linear accelerator as a new injector for the Separated Sector Cyclotron at the Heavy Ion Research Facility of LAN Zhou is being designed. The Drift-Tube-Linac (DTL) has been designed to accelerate ^238U^34+ from 0.140 MeV/u to 0.97 MeV/u [1]. The 3D finite element analysis of thermal behavior is presented in this paper. During operation, the cavity will produce Joule heat. The cavity will not work normally due to the high temperature and thermal deformation will lead to frequency drift, So it is necessary to perform thermal analysis to ensure the correct working temperature is used. The result of the analysis shows that after the water cooling system is put into the cavity the temperature rise is about 20 degrees and the frequency drift is about 0.15%.
ISSN:1674-1137
0254-3052
2058-6132
DOI:10.1088/1674-1137/35/10/012