A pulse shape discrimination of CsI(TI) crystal with 6He beam
The performance test of a CsI(TI) crystal (70×27×23 mm3) was performed by applying the pulse shape discrimination technique for identification of light charged particles. The crystal is coupled to a photomultiplier tube during an experiment with 6He beam. The pulse waveform is fully recorded by empl...
Gespeichert in:
Veröffentlicht in: | Nuclear science and techniques 2010 (1), p.35-38 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The performance test of a CsI(TI) crystal (70×27×23 mm3) was performed by applying the pulse shape discrimination technique for identification of light charged particles. The crystal is coupled to a photomultiplier tube during an experiment with 6He beam. The pulse waveform is fully recorded by employing a high precision digital oscilloscope. The fast and slow gates are used for the pulse shape discrimination and the best values for the gate widths were determined to be 0.5 μs and 1.67 μs, respectively. The 6He, 4He and 3He are successfully discriminated with this technique. |
---|---|
ISSN: | 1001-8042 2210-3147 |