Design and assembly of the CsI(T1) crystal module of the BESⅢ electro-magnetic calorimeter

The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics C 2008, Vol.32 (11), p.908-911
1. Verfasser: 董明义 蔡啸 方建 胡涛 赖元芬 刘春秀 吕军光 刘万金 尚雷 孙丽君 王志刚 夏小米 俞伯祥 周莉
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were found to work well before the installation of EMC.
ISSN:1674-1137
0254-3052