Optical readout uncooled infrared imaging detector using knife-edge filter operation

An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation (KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10.5 degree. A deformation magnifyi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:光电子快报:英文版 2007, Vol.3 (2), p.119-122
1. Verfasser: ZHANG Q MIAO Z GUO Z DONG F XIONG Z WU X CHEN D LI C JIAO B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation (KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10.5 degree. A deformation magnifying substrate-free micro-cantilever unit with multi-fold interval metaUized legs is specially designed and modeled. A FPA with 160×160 pixels is fabricated and thermal images with noise equivalent temperature difference (NETD) of 400 mK are obtained by this imaging detector.