Experimental Studies on High-Frequency Performance of the Inverse Control Magneto.Rheological Damper
Severe vibration of underground structures may be induced under blast loads. According to the characteristics of the explosion-induced ground shock wave, a new-type damper, inverse control magneto-rheological(MR) damper was designed to control the vibration, The high-frequency performance test of th...
Gespeichert in:
Veröffentlicht in: | Transactions of Tianjin University 2006-09, Vol.12 (B09), p.61-64 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Severe vibration of underground structures may be induced under blast loads. According to the characteristics of the explosion-induced ground shock wave, a new-type damper, inverse control magneto-rheological(MR) damper was designed to control the vibration, The high-frequency performance test of the MR damper was carried out on the small shaking table. It is shown that the performance can be modeled by use of the modified Bouc-Wen model, and the Parameters of the model keep stable in the range of 15--50 Hz. |
---|---|
ISSN: | 1006-4982 1995-8196 |