Wpływ zbrojenia styku na pracę statyczną żelbetowych belek zespolonych o przekroju teowym

The tests results of composite reinforced concrete T-shaped beams with an interface between the web and the flange are presented. The interface in the beams differed in the degree of the adhesion activity and the joining reinforcement ratio. Five series of beams were tested for deflection, displacem...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Budownictwo i Architektura 2020, Vol.19 (3), p.63-76
Hauptverfasser: Jabłoński, Łukasz, Halicka, Anna
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The tests results of composite reinforced concrete T-shaped beams with an interface between the web and the flange are presented. The interface in the beams differed in the degree of the adhesion activity and the joining reinforcement ratio. Five series of beams were tested for deflection, displacement of composite parts in relation to each other, strain of main and transverse reinforcement, and crack pattern. The results were compared with the theoretical forces, at which interface cracks and achieves the bearing capacity, calculated in accordance with fib Model Code 2010.
ISSN:1899-0665
2544-3275