MAŽAENERGIO PASTATO SIENOS-PAMATO ILGINIO ŠILUMINIO TILTELIO EFEKTYVUMO TYRIMAS
In this article, the authors carried out a research on a typical linear wall-foundation thermal bridge of a low-energy residential building, based on the principles of energy and economic efficiency. The empirical study showed that the most economical way to heat the foundation of a A + class reside...
Gespeichert in:
Veröffentlicht in: | Taikomieji tyrimai studijose ir praktikoje (Online) 2017, Vol.13 (1), p.130-136 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | lit |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this article, the authors carried out a research on a typical linear wall-foundation thermal bridge of a low-energy residential building, based on the principles of energy and economic efficiency. The empirical study showed that the most economical way to heat the foundation of a A + class residential building is with a continuous insulation thickness of 100 mm XPS200 (T3 position). In this position the linear wall-foundation thermal bridge is equal to 0,13 W/(mK). The annual cost per 1 meter of this connection is 0.84 €/m. The simple payback period is 30 years. By heating the foundation with 250 mm insulation thickness layer, the standard linear thermal bridge size (0.10 W/(mK)) is achieved, however this solution exceeds the economic life cycle of the material, and the payback can reach 65 years. Under other preconditions, the research shall be reviewed. |
---|---|