E-021 Quantitative Evaluation of Metal Artifact Reduction for Coiled Aneurysms in Cone-Beam CT

PurposeDuring minimally invasive embolization of brain aneurysms the aneurysm sac is filled with metal coils. The post-coiling cone-beam CT image quality is impaired by artifacts originating from the radiopaque metal mass. The artifact streaks run through the brain parenchyma, which hampers their in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neurointerventional surgery 2016-07, Vol.8 (Suppl 1), p.A56
Hauptverfasser: Ruijters, D, van de Haar, P, Kaila, G, Grünhagen, T, Moret, J, Spelle, L
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PurposeDuring minimally invasive embolization of brain aneurysms the aneurysm sac is filled with metal coils. The post-coiling cone-beam CT image quality is impaired by artifacts originating from the radiopaque metal mass. The artifact streaks run through the brain parenchyma, which hampers their inspection for hemorrhages and other events. Metal artifact reduction improves the image quality of cone-beam CT affected by streak artifacts. While several metal artifact reduction schemes have been described in the literature, there is little objective quantitative evaluation on clinical data. In this article we use pre- and post-coiling cone-beam CT data, and apply a metric (peak signal-to-noise ratio) to quantify the improvement in image quality.Materials and methodsFor 22 retrospective aneurysm coiling cases, cone-beam CT acquisitions prior and post embolization were available. The former dataset was used as gold standard reference to evaluate the latter without and with metal artifact reduction. To this purpose the pre- and post-coiling datasets were co-registered, and the brain cavity and coiling mass were segmented. The metric was then applied to the non-coiled brain parenchyma.ResultsThe mean squared error improved for 20 out of 22 patients after metal artifact reduction was applied. The average mean squared error was reduced by 264 HU. The peak signal-to-noise ratio was improved by 6.8 dB. The average additional computation time for the metal artifact reduction algorithm amounted 20 seconds.ConclusionMetal artifact reduction has been found to objectively improve the image quality quantified by the peak signal-to-noise ratio for most patients. It is therefore considered a useful tool for interventional use when the image contains metal parts.Abstract E-021 Figure 1DisclosuresD. Ruijters: 5; C; Philips Healthcare. P. van de Haar: 5; C; Philips Healthcare. G. Kaila: None. T. Grünhagen: 5; C; Philips Healthcare. J. Moret: None. L. Spelle: None.
ISSN:1759-8478
1759-8486
DOI:10.1136/neurintsurg-2016-012589.93