Design and Performance of the ALPS II Regeneration Cavity
The Regeneration Cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in t...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Regeneration Cavity (RC) is a critical component of the Any Light
Particle Search II (ALPS II) experiment. It increases the signal from possible
axions and axion-like particles in the experiment by nearly four orders of
magnitude. The total round-trip optical losses of the power circulating in the
cavity must be minimized in order to maximize the resonant enhancement of the
cavity, which is an important figure of merit for ALPS II. Lower optical losses
also increase the cavity storage time and with the 123 meter long ALPS II RC we
have demonstrated the longest storage time of a two-mirror optical cavity. We
measured a storage time of $7.17 \pm 0.01$ ms, equivalent to a linewidth of
44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm. |
---|---|
DOI: | 10.48550/arxiv.2408.13218 |