Reliability for Nerve Fiber Layer Reflectance Using Spectral Domain Optical Coherence Tomography
Purpose: Reliability for Nerve Fiber Layer Reflectance Using Spectral Domain Optical Coherence Tomography (OCT) Methods: The study utilized OCT to scan participants with a cubic 6x6 mm disc scan. NFL reflectance were normalized by the average of bands below NFL and summarized. We selected several re...
Gespeichert in:
Hauptverfasser: | , , , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: Reliability for Nerve Fiber Layer Reflectance Using Spectral Domain
Optical Coherence Tomography (OCT) Methods: The study utilized OCT to scan
participants with a cubic 6x6 mm disc scan. NFL reflectance were normalized by
the average of bands below NFL and summarized. We selected several reference
bands, including the pigment epithelium complex (PPEC), the band between NFL
and Bruch's membrane (Post-NFL), and the top 50% of pixels with higher values
were selected from the Post-NFL band by Post-NFL-Bright. Especially, we also
included NFL attenuation coefficient (AC), which was equivalent to NFL
reflectance normalized by all pixels below NFL. An experiment was designed to
test the NFL reflectance against different levels of attenuation using neutral
density filter (NDF). We also evaluated the within-visit and between-visit
repeatability using a clinical dataset with normal and glaucoma eyes. Results:
The experiment enrolled 20 healthy participants. The clinical dataset selected
22 normal and 55 glaucoma eyes with at least two visits form functional and
structural OCT (FSOCT) study. The experiment showed that NFL reflectance
normalized PPEC Max and Post-NFL-Bright had lowest dependence, slope=-0.77 and
-1.34 dB/optical density on NDF levels, respectively. The clinical data showed
that the NFL reflectance metrics normalized by Post-NFL-Bright or Post-NFL-Mean
metrics had a trend of better repeatability and reproducibility than others,
but the trend was not significant. All metrics demonstrated similar diagnostic
accuracy (0.82-0.87), but Post-NFL-Bright provide the best result. Conclusions:
The NFL reflectance normalized by the maximum in PPEC had less dependence of
the global attenuation followed by Post-NFL-Bright, PPEC/Mean, Post-NFL-Mean
and NFL/AC. But NFL reflectance normalized by Post-NFL-Bright had better result
in two datasets. |
---|---|
DOI: | 10.48550/arxiv.2406.00168 |