Thermal Models of Asteroids with Two-band Combinations of Wide-field Infrared Survey Explorer Cryogenic Data
We used the reparameterized Near-Earth Asteroid Thermal Model to model observations of a curated set of over 4000 asteroids from the Wide-field Infrared Survey Explorer in two wavelength bands (W2-3 or W3-4) and compared the results to previous results from all four wavelength bands (W1-4). This com...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2023-04 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We used the reparameterized Near-Earth Asteroid Thermal Model to model observations of a curated set of over 4000 asteroids from the Wide-field Infrared Survey Explorer in two wavelength bands (W2-3 or W3-4) and compared the results to previous results from all four wavelength bands (W1-4). This comparison was done with the goal of elucidating unique aspects of modeling two-band observations so that any potential biases or shortcomings for planned two-band surveys (e.g., the NASA Near-Earth Object Surveyor Mission) can be anticipated and quantified. The W2-3 two-band fits usually yielded slightly smaller diameters than the four-band fits, with a median diameter difference of -10%, with the 5% and 95% quantiles of the distribution at -32% and -1.5%, respectively. We conducted similar comparisons for W3-4, in part because the longest wavelength bands are expected to provide the best two-band results. We found that the W3-4 two-band diameters are slightly larger than the four-band results, with a median diameter difference of 11% and the 5% and 95% quantiles of the distribution at -2.1% and 26%, respectively. The diameter uncertainty, obtained with bootstrap analysis, is larger by 30% and 35% (median values) for the W2-3 and W3-4 fits, respectively, than for the corresponding four-band fits. Using 23 high-quality stellar occultation diameters as a benchmark, we found that the median errors of W2-3 and W3-4 diameter estimates are -15% and +12%, respectively, whereas the median error of the four-band fits is 9.3%. Although the W2-3 and W3-4 diameters appear to have greater systematic errors and uncertainties than their four-band counterparts, two-band estimates remain useful because they improve upon diameter estimates obtained from visible photometry alone. |
---|---|
ISSN: | 2331-8422 |
DOI: | 10.48550/arxiv.2304.06085 |