Influence of mechanical deformations on the performance of a coaxial shield for a cryogenic current comparator

This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2022-11
Hauptverfasser: Marsic, Nicolas, Müller, Wolfgang F O, Tympel, Volker, Stöhlker, Thomas, Stapelfeld, Max, Schmidl, Frank, Schmelz, Matthias, Zakosarenko, Vyacheslav, Stolz, Ronny, Haider, David, Sieber, Thomas, Schwickert, Marcus, De Gersem, Herbert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this paper also discusses the effect of mechanical vibrations on the CCC performance.