High-Accuracy Determination of Paul-Trap Stability Parameters for Electric-Quadrupole-Shift Prediction
The motion of an ion in a radiofrequency (rf) Paul trap is described by the Mathieu equation and the associated stability parameters that are proportional to the rf and dc electric field gradients. Here, a higher-order, iterative method to accurately solve the stability parameters from measured secu...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2022-09 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The motion of an ion in a radiofrequency (rf) Paul trap is described by the Mathieu equation and the associated stability parameters that are proportional to the rf and dc electric field gradients. Here, a higher-order, iterative method to accurately solve the stability parameters from measured secular frequencies is presented. It is then used to characterize an endcap trap by showing that the trap's radial asymmetry is dominated by the dc field gradients and by measuring the relation between the applied voltages and the gradients. The results are shown to be in good agreement with an electrostatic finite-element-method simulation of the trap. Furthermore, a method to determine the direction of the radial trap axes using a 'tickler' voltage is presented and the temperature dependence of the rf voltage is discussed. As an application for optical ion clocks, the method is used to predict and minimize the electric quadrupole shift (EQS) using the applied dc voltages. Finally, a lower limit of 1070 for the cancellation factor of the Zeeman-averaging EQS cancellation method is determined in an interleaved low/high EQS clock measurement. This reduces the EQS uncertainty of our \(^{88}\)Sr\(^+\) optical clock to \({\lesssim} 1\times 10^{-19}\) in fractional frequency units. |
---|---|
ISSN: | 2331-8422 |
DOI: | 10.48550/arxiv.2209.02290 |