A Survey of Left Atrial Appendage Segmentation and Analysis in 3D and 4D Medical Images
The 28th International Conference on Systems, Signals and Image Processing, IWSSIP 2021, Bratislava, Slovakia, 2021 Atrial fibrillation (AF) is a cardiovascular disease identified as one of the main risk factors for stroke. The majority of strokes due to AF are caused by clots originating in the lef...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The 28th International Conference on Systems, Signals and Image
Processing, IWSSIP 2021, Bratislava, Slovakia, 2021 Atrial fibrillation (AF) is a cardiovascular disease identified as one of the
main risk factors for stroke. The majority of strokes due to AF are caused by
clots originating in the left atrial appendage (LAA). LAA occlusion is an
effective procedure for reducing stroke risk. Planning the procedure using
pre-procedural imaging and analysis has shown benefits. The analysis is
commonly done by manually segmenting the appendage on 2D slices. Automatic LAA
segmentation methods could save an expert's time and provide insightful 3D
visualizations and accurate automatic measurements to aid in medical
procedures. Several semi- and fully-automatic methods for segmenting the
appendage have been proposed. This paper provides a review of automatic LAA
segmentation methods on 3D and 4D medical images, including CT, MRI, and
echocardiogram images. We classify methods into heuristic and model-based
methods, as well as into semi- and fully-automatic methods. We summarize and
compare the proposed methods, evaluate their effectiveness, and present current
challenges in the field and approaches to overcome them. |
---|---|
DOI: | 10.48550/arxiv.2205.06486 |