Low-order wavefront control using a Zernike sensor through Lyot coronagraphs for exoplanet imaging

Combining large segmented space telescopes, coronagraphy and wavefront control methods is a promising solution to produce a dark hole (DH) region in the coronagraphic image of an observed star and study planetary companions. The thermal and mechanical evolution of such a high-contrast facility leads...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2022-04
Hauptverfasser: Pourcelot, R, N'Diaye, M, Por, E H, Laginja, I, Carbillet, M, Benard, H, Brady, G, Canas, L, Dohlen, K, Fowler, J, Lai, O, Maclay, M, McChesney, E, Noss, J, Perrin, M D, Petrone, P, Pueyo, L, Redmond, S F, Sahoo, A, Vigan, A, Will, S D, Soummer, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Combining large segmented space telescopes, coronagraphy and wavefront control methods is a promising solution to produce a dark hole (DH) region in the coronagraphic image of an observed star and study planetary companions. The thermal and mechanical evolution of such a high-contrast facility leads to wavefront drifts that degrade the DH contrast during the observing time, thus limiting the ability to retrieve planetary signals. Lyot-style coronagraphs are starlight suppression systems that remove the central part of the image for an unresolved observed star, the point spread function, with an opaque focal plane mask (FPM). When implemented with a flat mirror containing an etched pinhole, the mask rejects part of the starlight through the pinhole which can be used to retrieve information about low-order aberrations. We propose an active control scheme using a Zernike wavefront sensor (ZWFS) to analyze the light rejected by the FPM, control low-order aberrations, and stabilize the DH contrast. The concept formalism is first presented before characterizing the sensor behavior in simulations and in laboratory. We then perform experimental tests to validate a wavefront control loop using a ZWFS on the HiCAT testbed. By controlling the first 11 Zernike modes, we show a decrease in wavefront error standard deviation by a factor of up to 9 between open- and closed-loop operations using the ZWFS. In the presence of wavefront perturbations, we show the ability of this control loop to stabilize a DH contrast around 7x10^-8 with a standard deviation of 7x10^-9. Active control with a ZWFS proves a promising solution in Lyot coronagraphs with an FPM-filtered beam to control and stabilize low-order wavefront aberrations and DH contrast for exoplanet imaging with future space missions.
ISSN:2331-8422
DOI:10.48550/arxiv.2204.06442