Image reconstruction from tissue scattered events for ${\beta}^{+}\gamma$ coincidences in Compton-PET
For long time non-pure beta emitters are avoided from PET imaging due to extra dose and increase in background from Compton scattering. But advent of high-resolution Compton camera system opens up new domain of imaging. Various non-pure beta emitters are formed as beam irradiation byproduct in thera...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | For long time non-pure beta emitters are avoided from PET imaging due to
extra dose and increase in background from Compton scattering. But advent of
high-resolution Compton camera system opens up new domain of imaging. Various
non-pure beta emitters are formed as beam irradiation byproduct in therapy
which can be used in online beam range verification. In this case, the number
of usable counts for imaging is generally 1-3 order lesser than normal PET
scan. On the other hand, we know that in human PET scanner, 30-60\% can be
tissue scattered coincidences in 3D case containing 80\% single scattered
events. In this work, we have investigated feasibility of imaging using only
single scattered coincidences for non-pure beta emitters in a Compton-PET
system. The locus of tissue scatter point can be reduced to in generally two
points after using Compton cone from both ends of 511 keV detections. Finally,
annihilation point is estimated using Compton cone of 1157 keV gamma and
time-of-flight information for the 511 keV. We believe independent assessment
of underlying activity from single scattered data sets will increase confidence
in image interpretation. |
---|---|
DOI: | 10.48550/arxiv.2110.01721 |