Search for explanation of the neutron lifetime anomaly
All results of the neutron lifetime measurements performed in the last 20 years with the UCN storage method are in a good agreement. These results are consistent with the latest most accurate measurements of the neutron decay asymmetry within the Standard Model. However, there is a significant discr...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2021-02 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | All results of the neutron lifetime measurements performed in the last 20 years with the UCN storage method are in a good agreement. These results are consistent with the latest most accurate measurements of the neutron decay asymmetry within the Standard Model. However, there is a significant discrepancy at \(3.6\sigma\) (1% of the decay probability) level between the averaged result of the storage method experiments and the most accurate measurements performed with the beam method. This article addresses the possible causes of such discrepancy. We focused on finding the spectrum of possible systematic corrections in the beam experiment. Four separate sources of the systematic errors which had not been properly addressed in articles dedicated to the beam technique were considered. Two of those sources are related with the motion of protons in an electromagnetic field and the elastic scattering by the residual gas. The third error concerns proton loss in the dead layer of the detector. It is shown the corresponding correction requires a more detailed analysis than that given in the papers describing the beam measurement method. The fourth source of the systematic error is the charge exchange process on the residual gas. The influence of that process was neglected in the beam method experiments. We present arguments that careful analysis of this issue is necessary since the proposed proton losses correction decreases the measured lifetime. For the problem of proton charge exchange on a residual gas, the spectrum of possible corrections is investigated. It is shown that for an accurate calculation of the correction, it is necessary to directly measure the concentration and composition of the residual gas inside the proton trap. The analysis reveals that even presence of only \(H_2\) molecules can lead to the significant correction which is the most probable explanation of the neutron anomaly. |
---|---|
ISSN: | 2331-8422 |
DOI: | 10.48550/arxiv.2011.13272 |