Regional Registration of Whole Slide Image Stacks Containing Highly Deformed Artefacts

Motivation: High resolution 2D whole slide imaging provides rich information about the tissue structure. This information can be a lot richer if these 2D images can be stacked into a 3D tissue volume. A 3D analysis, however, requires accurate reconstruction of the tissue volume from the 2D image sta...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Paknezhad, Mahsa, Loh, Sheng Yang Michael, Choudhury, Yukti, Koh, Valerie Koh Cui, Yong, TimothyTay Kwang, Tan, Hui Shan, Kanesvaran, Ravindran, Tan, Puay Hoon, Peng, John Yuen Shyi, Yu, Weimiao, Tan, Yongcheng Benjamin, Loy, Yong Zhen, Tan, Min-Han, Lee, Hwee Kuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Motivation: High resolution 2D whole slide imaging provides rich information about the tissue structure. This information can be a lot richer if these 2D images can be stacked into a 3D tissue volume. A 3D analysis, however, requires accurate reconstruction of the tissue volume from the 2D image stack. This task is not trivial due to the distortions that each individual tissue slice experiences while cutting and mounting the tissue on the glass slide. Performing registration for the whole tissue slices may be adversely affected by the deformed tissue regions. Consequently, regional registration is found to be more effective. In this paper, we propose an accurate and robust regional registration algorithm for whole slide images which incrementally focuses registration on the area around the region of interest. Results: Using mean similarity index as the metric, the proposed algorithm (mean $\pm$ std: $0.84 \pm 0.11$) followed by a fine registration algorithm ($0.86 \pm 0.08$) outperformed the state-of-the-art linear whole tissue registration algorithm ($0.74 \pm 0.19$) and the regional version of this algorithm ($0.81 \pm 0.15$). The proposed algorithm also outperforms the state-of-the-art nonlinear registration algorithm (original : $0.82 \pm 0.12$, regional : $0.77 \pm 0.22$) for whole slide images and a recently proposed patch-based registration algorithm (patch size 256: $0.79 \pm 0.16$ , patch size 512: $0.77 \pm 0.16$) for medical images. Availability: The C++ implementation code is available online at the github repository: https://github.com/MahsaPaknezhad/WSIRegistration
DOI:10.48550/arxiv.2002.12588