Single-layer Compton detectors for measurement of polarization correlations of annihilation quanta
Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since polarization can be measured via Compton scattering, the initial ort...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2020-02 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since polarization can be measured via Compton scattering, the initial orthogonality of polarizations can be translated to correlation of azimuthal scattering angles, and this correlation may be exploited as an additional handle to identify the true coincidence events. To examine the concept of using the polarization correlations in PET, we have used a system of two compact, position and energy-sensitive Compton detectors in coincidence mode. Each consists of a single matrix of scintillation pixels, read-out by an array of Silicon photomultipliers. The Compton events in each module are clearly identified and the scattering angles are reconstructed from the energy deposition and event topology. We have extracted the polarimetric modulation factors from the distributions of the difference of the azimuthal angles of the two Compton-scattered gammas and studied their dependence on Compton scattering angles \(\theta\) and on azimuthal resolution \(\Delta\phi\). For scattering angles around \(\theta_{1,2}=82^\circ\), where the maximum modulation is expected, the modulation factors from \(\mu=0.15\pm 0.01\) to \(\mu=0.27\pm 0.02\) have been measured, depending on the azimuthal resolution, which is governed by event topology in the detectors. Analogously, for scattering around \(\theta_{1,2}=70^\circ\), modulation factors from \(\mu=0.12\pm 0.01\) to \(\mu=0.21\pm 0.02\) have been obtained. The results show that the measurement of the polarization correlations of annihilation quanta are feasible with compact single-layer, single-side read-out detectors, which may be used to build cost-efficient systems for various applications where gamma-ray polarization information is of interest. |
---|---|
ISSN: | 2331-8422 |
DOI: | 10.48550/arxiv.1910.11940 |