Ultra-Sensitive Radio Frequency Biosensor at an Exceptional Point of Degeneracy induced by Time Modulation
We exploit the premises of exceptional points of degeneracy (EPDs) induced in linear time-periodic (LTP) systems to achieve extremely sensitive biosensors. The EPD is formed in a single LC resonator where the total capacitance is comprised of a time-varying capacitor in parallel to a biosensing capa...
Gespeichert in:
Hauptverfasser: | , , , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We exploit the premises of exceptional points of degeneracy (EPDs) induced in
linear time-periodic (LTP) systems to achieve extremely sensitive biosensors.
The EPD is formed in a single LC resonator where the total capacitance is
comprised of a time-varying capacitor in parallel to a biosensing capacitor. We
use the time-periodic variation of a system parameter (e.g., capacitance) to
achieve a second order EPD aiming at improving the sensitivity of liquid based
radio frequency biosensors, leading to an intrinsic ultra sensitivity. We show
the emergence of EPDs in such a system and the ultra sensitivity of the
degenerate resonance frequency to perturbations compared to conventional RF
sensors. Moreover, we investigate the capacitance and conductance variations of
an interdigitated biosensing capacitor to the changes in the concentration of a
biological material under test (MUT), leading to subsequent large changes in
the resonance frequency of the LTP-LC resonator. A comparison with a standard
LC resonator demonstrates the ultra-high sensitivity of the proposed LTP-LC
based biosensor. In addition, we show the scalability of the biosensor
sensitivity across different frequency ranges. |
---|---|
DOI: | 10.48550/arxiv.1909.03344 |