The application of muon tomography to the imaging of railway tunnels

Cosmic Ray Muon Radiography utilizes highly-penetrating cosmic ray muons to image the density profile of an object of interest. Here we report on the first trial to use a portable field-deployable cosmic ray tracking system in order to image the whole overburden of a UK railway tunnel with short dur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2019-06
Hauptverfasser: Thompson, L F, Stowell, J P, Fargher, S J, Steer, C A, Loughney, K L, O'Sullivan, E M, Gluyas, J G, Blaney, S W, Pidcock, R J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cosmic Ray Muon Radiography utilizes highly-penetrating cosmic ray muons to image the density profile of an object of interest. Here we report on the first trial to use a portable field-deployable cosmic ray tracking system in order to image the whole overburden of a UK railway tunnel with short duration scans (c. 30 minutes). A unknown overburden void was identified and, post-trial, confirmed by railway authorities. These experiments demonstrate the identification of hidden construction shafts with high levels of statistical significance as density anomalies within the data.
ISSN:2331-8422
DOI:10.48550/arxiv.1906.05814