MWPC prototyping and performance test for the STAR inner TPC upgrade
A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6\(\%\) and wire pitch precision better than 10 \(\mu\)m. The gas gain uniformity an...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2018-05 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6\(\%\) and wire pitch precision better than 10 \(\mu\)m. The gas gain uniformity and energy resolution are measured to be better than 1\(\%\) (RMS) and 20\(\%\) (FWHM), respectively, using an \(^{55}\)Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. The test results show that the constructed iTPC prototype meets all project requirements. |
---|---|
ISSN: | 2331-8422 |