Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2014-08
Hauptverfasser: Collaboration, CUORE, Avignone, F T, Azzolini, O, Balata, M, Banks, T I, Bari, G, Beeman, J, Bellini, F, Bersani, A, Brofferio, C, Bucci, C, Cai, X Z, Canonica, L, Cao, X G, Capelli, S, Carbone, L, Cardani, L, Casali, N, Chiesa, D, Clemenza, M, Cosmelli, C, Cremonesi, O, Creswick, R J, Dafinei, I, Dally, A, Datskov, V, Deninno, M M, S Di Domizio, di Vacri, M L, Ejzak, L, Fang, D Q, Faverzani, M, Fernandes, G, Ferri, E, Fiorini, E, Freedman, S J, Fujikawa, B K, Giachero, A, Gironi, L, Giuliani, A, Goett, J, Gorla, P, Gotti, C, Gutierrez, T D, Haller, E E, Han, K, Heeger, K M, Hennings-Yeomans, R, Huang, H Z, Kadel, R, Kazkaz, K, Keppel, G, Kolomensky, Yu G, Li, Y L, Lim, K E, Ma, Y G, Maiano, C, Maino, M, Martinez, M, Maruyama, R H, Mei, Y, Moggi, N, Nones, C, Norman, E B, Nucciotti, A, Orlandi, D, Ouellet, J L, Pallavicini, M, Palmieri, V, Pattavina, L, Pavan, M, Pessina, G, Pettinacci, V, Piperno, G, Pirro, S, Rosenfeld, C, Rusconi, C, Sala, E, Sangiorgio, S, Scielzo, N D, Sisti, M, Smith, A R, Taffarello, L, Tenconi, M, Terranova, F, Tian, W D, Tomei, C, Trentalange, S, Ventura, G, Vignati, M, Wang, B S, Wang, H W, Wielgus, L, Wilson, J, Winslow, L A, Wise, T, Zanotti, L, Zarra, C, Zhu, B X, Zucchelli, S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the {\alpha} background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
ISSN:2331-8422
DOI:10.48550/arxiv.1402.0922