MoO2 and N‑Doped Carbon Nano-Octahedron Nanozymes for Sensitive Detection of Alkaline Phosphatase

As a typical biomarker for clinical diagnosis of diseases, alkaline phosphatase (ALP) plays a crucial role in regulating the dephosphorylation of biomolecules. Consequently, it is necessary to develop an effective and simple method for the determination of ALP activity. In this work, we report a cat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACS applied nano materials 2023-05, Vol.6 (9), p.7775-7784
Hauptverfasser: Xue, Liuheng, Wang, Gang, Liu, Jia, Feng, Qinghua, Liu, Meili, Wang, Yingsha, Zhang, Shouting, Hu, Wenping
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:As a typical biomarker for clinical diagnosis of diseases, alkaline phosphatase (ALP) plays a crucial role in regulating the dephosphorylation of biomolecules. Consequently, it is necessary to develop an effective and simple method for the determination of ALP activity. In this work, we report a catalytic reaction-based colorimetric method to monitor ALP activity by using a nanostructured MoO2@NP-doped carbon nano-octahedron (MoO2@NPC) as a favorable oxidase mimetic. Because the C–O bond generated in the nano-octahedron MoO2@NPC regulates the electronic valence state of Mo between +5 and +6, the as-prepared MoO2@NPC regular octahedron with good peroxide-like (POD-like) properties and colorless 3,3′,5,5′-tetramethylbenzidine dihydrochloride hydrate (TMB) can be catalyzed to dark-blue oxTMB. When ALP hydrolyzes the substrate AAP, the produced AA with a certain reducing ability can not only reduce oxTMB to TMB but also consume hydroxyl radicals (•OH) generated in the MoO2@NPC/H2O2/TMB system, which significantly inhibits the color reaction of TMB. On this basis, a simple and efficient colorimetric method for ALP was constructed based on carbon-based nanozymes. Furthermore, the system goes for the detection of ALP with high sensitivity for the first time. The linearity is good in the range of 0.5–30 U/L, and the detection limit was 0.02 U/L and had good stability and reproducibility. Reliable and accurate measurements of analytes in real samples were also validated by our analytical method, showing that it can provide a reliable, convenient, and efficient nanoplatform for clinical diagnosis of ALP activity.
ISSN:2574-0970
2574-0970
DOI:10.1021/acsanm.3c00846