Characterization of the Electrical Environment

A communication system must have adequate electrical protection in order to meet the reliability standards for commercially acceptable service and to keep down maintenance expenses. This report characterizes, from the viewpoint of electrical protection and coordination, the conditions of the electri...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bodle, David (VerfasserIn), Ghazi, Axel (VerfasserIn), Syed, Moninuddin (VerfasserIn)
Format: Elektronisch E-Book
Sprache:English
Veröffentlicht: Toronto University of Toronto Press [2019]
Schriftenreihe:Heritage
Schlagworte:
Online-Zugang:FAW01
FHA01
FKE01
FLA01
UPA01
FAB01
FCO01
URL des Erstveröffentlichers
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!

MARC

LEADER 00000nmm a2200000zc 4500
001 BV045929038
003 DE-604
005 00000000000000.0
007 cr|uuu---uuuuu
008 190612s2019 |||| o||u| ||||||eng d
020 |a 9781442632172  |9 978-1-4426-3217-2 
024 7 |a 10.3138/9781442632172  |2 doi 
035 |a (ZDB-23-DGG)9781442632172 
035 |a (OCoLC)1104855511 
035 |a (DE-599)BVBBV045929038 
040 |a DE-604  |b ger  |e rda 
041 0 |a eng 
049 |a DE-1046  |a DE-739  |a DE-860  |a DE-859  |a DE-Aug4  |a DE-1043  |a DE-858 
082 0 |a 621.38/028 
100 1 |a Bodle, David  |e Verfasser  |4 aut 
245 1 0 |a Characterization of the Electrical Environment  |c Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle 
264 1 |a Toronto  |b University of Toronto Press  |c [2019] 
264 4 |c © 1976 
300 |a 1 online resource 
336 |b txt  |2 rdacontent 
337 |b c  |2 rdamedia 
338 |b cr  |2 rdacarrier 
490 0 |a Heritage 
500 |a Description based on online resource; title from PDF title page (publisher's Web site, viewed 30. Apr 2019) 
520 |a A communication system must have adequate electrical protection in order to meet the reliability standards for commercially acceptable service and to keep down maintenance expenses. This report characterizes, from the viewpoint of electrical protection and coordination, the conditions of the electrical environment to which communication facilities are exposed. It gives consideration to both present and anticipated future conditions, and covers such topics as the effects of lightning, interference from power networks, electric shock, earth potential gradients, corrosion, over-voltage in AC power utilization circuits,her and electromagnetic pulses.Characterization of the Electrical Environment is a current reference on the design factors required to ensure reliable performance of communication facilities under field operating conditions. It will be useful as a manual for practicing engineers in telecommunications, and as a tutorial textbook in engineering schools in North America, Europe, and elsewhere 
546 |a In English 
650 7 |a Technology & Engineering / Electrical  |2 bisacsh 
650 4 |a Electric currents 
650 4 |a Electric lines  |x Protection 
650 4 |a Electric power systems  |x Protection 
650 4 |a Electric shock 
700 1 |a Ghazi, Axel  |4 aut 
700 1 |a Syed, Moninuddin  |4 aut 
856 4 0 |u https://doi.org/10.3138/9781442632172  |x Verlag  |z URL des Erstveröffentlichers  |3 Volltext 
912 |a ZDB-23-DGG 
999 |a oai:aleph.bib-bvb.de:BVB01-031311475 
966 e |u https://doi.org/10.3138/9781442632172  |l FAW01  |p ZDB-23-DGG  |q FAW_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l FHA01  |p ZDB-23-DGG  |q FHA_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l FKE01  |p ZDB-23-DGG  |q FKE_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l FLA01  |p ZDB-23-DGG  |q FLA_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l UPA01  |p ZDB-23-DGG  |q UPA_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l FAB01  |p ZDB-23-DGG  |q FAB_PDA_DGG  |x Verlag  |3 Volltext 
966 e |u https://doi.org/10.3138/9781442632172  |l FCO01  |p ZDB-23-DGG  |q FCO_PDA_DGG  |x Verlag  |3 Volltext 

Datensatz im Suchindex

_version_ 1804180114957664256
any_adam_object
author Bodle, David
Ghazi, Axel
Syed, Moninuddin
author_facet Bodle, David
Ghazi, Axel
Syed, Moninuddin
author_role aut
aut
aut
author_sort Bodle, David
author_variant d b db
a g ag
m s ms
building Verbundindex
bvnumber BV045929038
collection ZDB-23-DGG
ctrlnum (ZDB-23-DGG)9781442632172
(OCoLC)1104855511
(DE-599)BVBBV045929038
dewey-full 621.38/028
dewey-hundreds 600 - Technology (Applied sciences)
dewey-ones 621 - Applied physics
dewey-raw 621.38/028
dewey-search 621.38/028
dewey-sort 3621.38 228
dewey-tens 620 - Engineering and allied operations
discipline Elektrotechnik / Elektronik / Nachrichtentechnik
doi_str_mv 10.3138/9781442632172
format Electronic
eBook
fullrecord <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>03328nmm a2200541zc 4500</leader><controlfield tag="001">BV045929038</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">00000000000000.0</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">190612s2019 |||| o||u| ||||||eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9781442632172</subfield><subfield code="9">978-1-4426-3217-2</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3138/9781442632172</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-23-DGG)9781442632172</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1104855511</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV045929038</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-1046</subfield><subfield code="a">DE-739</subfield><subfield code="a">DE-860</subfield><subfield code="a">DE-859</subfield><subfield code="a">DE-Aug4</subfield><subfield code="a">DE-1043</subfield><subfield code="a">DE-858</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">621.38/028</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Bodle, David</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Characterization of the Electrical Environment</subfield><subfield code="c">Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Toronto</subfield><subfield code="b">University of Toronto Press</subfield><subfield code="c">[2019]</subfield></datafield><datafield tag="264" ind1=" " ind2="4"><subfield code="c">© 1976</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 online resource</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="0" ind2=" "><subfield code="a">Heritage</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Description based on online resource; title from PDF title page (publisher's Web site, viewed 30. Apr 2019)</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A communication system must have adequate electrical protection in order to meet the reliability standards for commercially acceptable service and to keep down maintenance expenses. This report characterizes, from the viewpoint of electrical protection and coordination, the conditions of the electrical environment to which communication facilities are exposed. It gives consideration to both present and anticipated future conditions, and covers such topics as the effects of lightning, interference from power networks, electric shock, earth potential gradients, corrosion, over-voltage in AC power utilization circuits,her and electromagnetic pulses.Characterization of the Electrical Environment is a current reference on the design factors required to ensure reliable performance of communication facilities under field operating conditions. It will be useful as a manual for practicing engineers in telecommunications, and as a tutorial textbook in engineering schools in North America, Europe, and elsewhere</subfield></datafield><datafield tag="546" ind1=" " ind2=" "><subfield code="a">In English</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Technology &amp; Engineering / Electrical</subfield><subfield code="2">bisacsh</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electric currents</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electric lines</subfield><subfield code="x">Protection</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electric power systems</subfield><subfield code="x">Protection</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electric shock</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ghazi, Axel</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Syed, Moninuddin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="x">Verlag</subfield><subfield code="z">URL des Erstveröffentlichers</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-23-DGG</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-031311475</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FAW01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FAW_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FHA01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FHA_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FKE01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FKE_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FLA01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FLA_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">UPA01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">UPA_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FAB01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FAB_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.3138/9781442632172</subfield><subfield code="l">FCO01</subfield><subfield code="p">ZDB-23-DGG</subfield><subfield code="q">FCO_PDA_DGG</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield></record></collection>
id DE-604.BV045929038
illustrated Not Illustrated
indexdate 2024-07-10T08:30:37Z
institution BVB
isbn 9781442632172
language English
oai_aleph_id oai:aleph.bib-bvb.de:BVB01-031311475
oclc_num 1104855511
open_access_boolean
owner DE-1046
DE-739
DE-860
DE-859
DE-Aug4
DE-1043
DE-858
owner_facet DE-1046
DE-739
DE-860
DE-859
DE-Aug4
DE-1043
DE-858
physical 1 online resource
psigel ZDB-23-DGG
ZDB-23-DGG FAW_PDA_DGG
ZDB-23-DGG FHA_PDA_DGG
ZDB-23-DGG FKE_PDA_DGG
ZDB-23-DGG FLA_PDA_DGG
ZDB-23-DGG UPA_PDA_DGG
ZDB-23-DGG FAB_PDA_DGG
ZDB-23-DGG FCO_PDA_DGG
publishDate 2019
publishDateSearch 2019
publishDateSort 2019
publisher University of Toronto Press
record_format marc
series2 Heritage
spelling Bodle, David Verfasser aut
Characterization of the Electrical Environment Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle
Toronto University of Toronto Press [2019]
© 1976
1 online resource
txt rdacontent
c rdamedia
cr rdacarrier
Heritage
Description based on online resource; title from PDF title page (publisher's Web site, viewed 30. Apr 2019)
A communication system must have adequate electrical protection in order to meet the reliability standards for commercially acceptable service and to keep down maintenance expenses. This report characterizes, from the viewpoint of electrical protection and coordination, the conditions of the electrical environment to which communication facilities are exposed. It gives consideration to both present and anticipated future conditions, and covers such topics as the effects of lightning, interference from power networks, electric shock, earth potential gradients, corrosion, over-voltage in AC power utilization circuits,her and electromagnetic pulses.Characterization of the Electrical Environment is a current reference on the design factors required to ensure reliable performance of communication facilities under field operating conditions. It will be useful as a manual for practicing engineers in telecommunications, and as a tutorial textbook in engineering schools in North America, Europe, and elsewhere
In English
Technology & Engineering / Electrical bisacsh
Electric currents
Electric lines Protection
Electric power systems Protection
Electric shock
Ghazi, Axel aut
Syed, Moninuddin aut
https://doi.org/10.3138/9781442632172 Verlag URL des Erstveröffentlichers Volltext
spellingShingle Bodle, David
Ghazi, Axel
Syed, Moninuddin
Characterization of the Electrical Environment
Technology & Engineering / Electrical bisacsh
Electric currents
Electric lines Protection
Electric power systems Protection
Electric shock
title Characterization of the Electrical Environment
title_auth Characterization of the Electrical Environment
title_exact_search Characterization of the Electrical Environment
title_full Characterization of the Electrical Environment Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle
title_fullStr Characterization of the Electrical Environment Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle
title_full_unstemmed Characterization of the Electrical Environment Moninuddin Syed, Ralph Woodside, Axel Ghazi, David Bodle
title_short Characterization of the Electrical Environment
title_sort characterization of the electrical environment
topic Technology & Engineering / Electrical bisacsh
Electric currents
Electric lines Protection
Electric power systems Protection
Electric shock
topic_facet Technology & Engineering / Electrical
Electric currents
Electric lines Protection
Electric power systems Protection
Electric shock
url https://doi.org/10.3138/9781442632172
work_keys_str_mv AT bodledavid characterizationoftheelectricalenvironment
AT ghaziaxel characterizationoftheelectricalenvironment
AT syedmoninuddin characterizationoftheelectricalenvironment