Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen

Gespeichert in:
Bibliographische Detailangaben
Format: Tagungsbericht Buch
Sprache:German
Veröffentlicht: Stuttgart Enke 1997
Schlagworte:
Online-Zugang:Inhaltsverzeichnis
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!

MARC

LEADER 00000nam a2200000 c 4500
001 BV011281315
003 DE-604
005 19970616
007 t|
008 970325s1997 gw ad|| |||| 00||| ger d
016 7 |a 949960276  |2 DE-101 
020 |a 343229901X  |c kart. : ca. DM 128.00, ca. sfr 113.00, ca. S 934.00  |9 3-432-29901-X 
035 |a (OCoLC)38121138 
035 |a (DE-599)BVBBV011281315 
040 |a DE-604  |b ger  |e rakddb 
041 0 |a ger 
044 |a gw  |c DE 
049 |a DE-20 
082 0 |a 617.5810592 
245 1 0 |a Performance of the wear couple BIOLOX forte in hip arthroplasty  |b proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen  |c hrsg. von Wolfhart Puhl 
264 1 |a Stuttgart  |b Enke  |c 1997 
300 |a 141 S.  |b Ill., graph. Darst. 
336 |b txt  |2 rdacontent 
337 |b n  |2 rdamedia 
338 |b nc  |2 rdacarrier 
500 |a Literaturangaben 
650 4 |a Biocompatible Materials  |v Congresses 
650 4 |a Ceramics  |v Congresses 
650 4 |a Clinical Trials as Topic  |v Congresses 
650 4 |a Hip Prosthesis  |v Congresses 
650 4 |a Treatment Outcome  |v Congresses 
650 0 7 |a Biokeramik  |0 (DE-588)4371693-3  |2 gnd  |9 rswk-swf 
650 0 7 |a Hüftgelenkprothese  |0 (DE-588)4026034-3  |2 gnd  |9 rswk-swf 
650 0 7 |a Werkstoffpaarung  |0 (DE-588)4130269-2  |2 gnd  |9 rswk-swf 
655 7 |0 (DE-588)1071861417  |a Konferenzschrift  |y 1997  |z Stuttgart  |2 gnd-content 
689 0 0 |a Hüftgelenkprothese  |0 (DE-588)4026034-3  |D s 
689 0 1 |a Biokeramik  |0 (DE-588)4371693-3  |D s 
689 0 2 |a Werkstoffpaarung  |0 (DE-588)4130269-2  |D s 
689 0 |5 DE-604 
700 1 |a Puhl, Wolfhart  |d 1939-  |e Sonstige  |0 (DE-588)115379517  |4 oth 
711 2 |a Symposium on Ceramic Wear Couple  |n 2  |d 1997  |c Stuttgart  |j Sonstige  |0 (DE-588)2162629-7  |4 oth 
856 4 2 |m HBZ Datenaustausch  |q application/pdf  |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=007576166&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA  |3 Inhaltsverzeichnis 
943 1 |a oai:aleph.bib-bvb.de:BVB01-007576166 

Datensatz im Suchindex

_version_ 1819646548284276736
adam_text Inhalt 1 The Wear Problem in THR Das Probleme des Abriebs in der Hüftendoprothetik J. Black 1.1 Prospects for Alternate Bearing Surfaces in Total Replacement Arthroplasty of the Hip . . 2 J. Jerosch, S. Fuchs, R. Reichelt, S. Haftka 1.2 Probleme des Implantatwerkstoffes ultrahochmolekulares Polyethylen (UHMWPE) .... 11 W.Baur 1.3 Das Konzept „Metall Metall Artikulation beim künstlichen Hüftgelenksersatz 23 2 Clinical Experience with BIOLOX® forte Cup Inserts Klinische Erfahrungen mit Pfanneneinsätzen aus BIOLOX® forte A. Toni, A. Sudanese, S. Terzi, G. Barbanti Brodano, L. Brizio, S. Paderni, G. Nasta, D. Nardi 2.1 Ceramic in Total Hip Arthroplasty 30 L. Fantasia, D. Cornacchia, M. Agamennone, P. La Floresta 2.2 A Bipolar Cup with Ceramic Insert for the Hip Degenerative Pathology: Early Experiences 34 F. Bonicoli, L. Rughini, P.P. Lunati, G. Di Puccio, St. Secone, E. Bonicoli 2.3 Ceramic Insert in Uncemented Press fit Titanium Total Hip Prostheses. Our Clinical Experiences in Fifty nine Cases 38 D. Rueda, M. Älvarez, F. Barahona, J. Gömez Canedo 2.4 Ceramic Inserts in Metal Cups. A Five year Experience 43 J. Fenollosa, J.M. Aparisi, P. Seminario 2.5 Ceramic ceramic in THR. Fifteen year of Experience, with 262 Cases 50 G. Gualtieri, D. Dallari, P. Calderoni, I. Gualtieri 2.6 Hip Arthroprosthesis with Ceramic to Ceramic Coupling: Experimental Tests and Clinical Trials 58 B. Maaz, T.J. Schlegel 2.7 Erfahrungen mit dem Kaiserswerther Pfannensystem (Metallschraubring mit Keramikinlay) 6] C. Franke, D. Stock 2.8 Monolithische versus modular aufgebaute, zementfreie Keramik Hüft Endoprothesen ... 62 G. Quack, G. Willmann, H. Krahl, H. Grundei 2.9 Weiterentwicklung des ESKA Spongiosametall Pfannensystems durch die BIOLOX8 forte Gleitpaarung 65 R. Widhalm, A. Kamer, Ch. Gebhart 2.10 Die Variopfanne mit Preßfitverankerung und Keramik Gleitpaarung. Konzept und erste Ergebnisse 77 M. Menge, J. Hesse 2.11 Mittelfristige Ergebnisse mit dem Sl Schraubring mit Keramik Inserts 81 P Lubimts 2.12 Das Konzept des funktionsgeschützten Keramiklagers (FGK) 85 3 Reliability of Total Hip Replacement Sicherheit von Hüftendoprothesen J.P. Garino 3.1 The United States Food and Drug Administration and its Regulation of Medical Devices 92 W. Blömer 3.2 Design Aspects of Modular Inlay Fixation 95 G. Willmann 3.3 BIOLOX forte Heads and Cup Inserts for THR What a Surgeon Should Know 105 V. Saikko, H. G. Pfaff 3.4 Wear of Alumina on alumina Total Replacement Hip Joints Studied with a Hip Joint Simulator 117 A. Walter 3.5 Investigations on the Wear Couple BIOLOX® forte/BIOLOX® forte and Earlier Alumina Materials 123 P. Dalla Pria, L. Bregant, F. Di Marino 3.6 Stiffness of the Acetabular Cups: A Comparative Study Using the Finite Element Method 136 G. Willmann 3.7 Wie darf man keramische Komponenten für Hüftendoprothesen sterilisieren? 139
any_adam_object 1
author_GND (DE-588)115379517
building Verbundindex
bvnumber BV011281315
ctrlnum (OCoLC)38121138
(DE-599)BVBBV011281315
dewey-full 617.5810592
dewey-hundreds 600 - Technology (Applied sciences)
dewey-ones 617 - Surgery & related medical specialties
dewey-raw 617.5810592
dewey-search 617.5810592
dewey-sort 3617.5810592
dewey-tens 610 - Medicine and health
discipline Medizin
format Conference Proceeding
Book
fullrecord <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>02082nam a2200481 c 4500</leader><controlfield tag="001">BV011281315</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">19970616 </controlfield><controlfield tag="007">t|</controlfield><controlfield tag="008">970325s1997 gw ad|| |||| 00||| ger d</controlfield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">949960276</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">343229901X</subfield><subfield code="c">kart. : ca. DM 128.00, ca. sfr 113.00, ca. S 934.00</subfield><subfield code="9">3-432-29901-X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)38121138</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV011281315</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="044" ind1=" " ind2=" "><subfield code="a">gw</subfield><subfield code="c">DE</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-20</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">617.5810592</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Performance of the wear couple BIOLOX forte in hip arthroplasty</subfield><subfield code="b">proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen</subfield><subfield code="c">hrsg. von Wolfhart Puhl</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Stuttgart</subfield><subfield code="b">Enke</subfield><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">141 S.</subfield><subfield code="b">Ill., graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Literaturangaben</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Biocompatible Materials</subfield><subfield code="v">Congresses</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Ceramics</subfield><subfield code="v">Congresses</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Clinical Trials as Topic</subfield><subfield code="v">Congresses</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Hip Prosthesis</subfield><subfield code="v">Congresses</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Treatment Outcome</subfield><subfield code="v">Congresses</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Biokeramik</subfield><subfield code="0">(DE-588)4371693-3</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Hüftgelenkprothese</subfield><subfield code="0">(DE-588)4026034-3</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Werkstoffpaarung</subfield><subfield code="0">(DE-588)4130269-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)1071861417</subfield><subfield code="a">Konferenzschrift</subfield><subfield code="y">1997</subfield><subfield code="z">Stuttgart</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">Hüftgelenkprothese</subfield><subfield code="0">(DE-588)4026034-3</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="1"><subfield code="a">Biokeramik</subfield><subfield code="0">(DE-588)4371693-3</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="2"><subfield code="a">Werkstoffpaarung</subfield><subfield code="0">(DE-588)4130269-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Puhl, Wolfhart</subfield><subfield code="d">1939-</subfield><subfield code="e">Sonstige</subfield><subfield code="0">(DE-588)115379517</subfield><subfield code="4">oth</subfield></datafield><datafield tag="711" ind1="2" ind2=" "><subfield code="a">Symposium on Ceramic Wear Couple</subfield><subfield code="n">2</subfield><subfield code="d">1997</subfield><subfield code="c">Stuttgart</subfield><subfield code="j">Sonstige</subfield><subfield code="0">(DE-588)2162629-7</subfield><subfield code="4">oth</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">HBZ Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&amp;doc_library=BVB01&amp;local_base=BVB01&amp;doc_number=007576166&amp;sequence=000002&amp;line_number=0001&amp;func_code=DB_RECORDS&amp;service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-007576166</subfield></datafield></record></collection>
genre (DE-588)1071861417 Konferenzschrift 1997 Stuttgart gnd-content
genre_facet Konferenzschrift 1997 Stuttgart
id DE-604.BV011281315
illustrated Illustrated
indexdate 2024-12-23T14:28:20Z
institution BVB
institution_GND (DE-588)2162629-7
isbn 343229901X
language German
oai_aleph_id oai:aleph.bib-bvb.de:BVB01-007576166
oclc_num 38121138
open_access_boolean
owner DE-20
owner_facet DE-20
physical 141 S. Ill., graph. Darst.
publishDate 1997
publishDateSearch 1997
publishDateSort 1997
publisher Enke
record_format marc
spellingShingle Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen
Biocompatible Materials Congresses
Ceramics Congresses
Clinical Trials as Topic Congresses
Hip Prosthesis Congresses
Treatment Outcome Congresses
Biokeramik (DE-588)4371693-3 gnd
Hüftgelenkprothese (DE-588)4026034-3 gnd
Werkstoffpaarung (DE-588)4130269-2 gnd
subject_GND (DE-588)4371693-3
(DE-588)4026034-3
(DE-588)4130269-2
(DE-588)1071861417
title Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen
title_auth Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen
title_exact_search Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen
title_full Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen hrsg. von Wolfhart Puhl
title_fullStr Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen hrsg. von Wolfhart Puhl
title_full_unstemmed Performance of the wear couple BIOLOX forte in hip arthroplasty proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen hrsg. von Wolfhart Puhl
title_short Performance of the wear couple BIOLOX forte in hip arthroplasty
title_sort performance of the wear couple biolox forte in hip arthroplasty proceedings of the 2nd symposium on ceramic wear couple march 8 1997 stuttgart germany 42 tabellen
title_sub proceedings of the 2nd Symposium on Ceramic Wear Couple, March 8, 1997 Stuttgart (Germany) ; 42 Tabellen
topic Biocompatible Materials Congresses
Ceramics Congresses
Clinical Trials as Topic Congresses
Hip Prosthesis Congresses
Treatment Outcome Congresses
Biokeramik (DE-588)4371693-3 gnd
Hüftgelenkprothese (DE-588)4026034-3 gnd
Werkstoffpaarung (DE-588)4130269-2 gnd
topic_facet Biocompatible Materials Congresses
Ceramics Congresses
Clinical Trials as Topic Congresses
Hip Prosthesis Congresses
Treatment Outcome Congresses
Biokeramik
Hüftgelenkprothese
Werkstoffpaarung
Konferenzschrift 1997 Stuttgart
url http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=007576166&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA
work_keys_str_mv AT puhlwolfhart performanceofthewearcouplebioloxforteinhiparthroplastyproceedingsofthe2ndsymposiumonceramicwearcouplemarch81997stuttgartgermany42tabellen
AT symposiumonceramicwearcouplestuttgart performanceofthewearcouplebioloxforteinhiparthroplastyproceedingsofthe2ndsymposiumonceramicwearcouplemarch81997stuttgartgermany42tabellen