SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy

Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study it...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2016-06, Vol.43 (6), p.3623-3623
Hauptverfasser: Hueso-Gonzalez, F, Vijande, J, Ballester, F, Perez-Calatayud, J, Siebert, F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3623
container_issue 6
container_start_page 3623
container_title Medical physics (Lancaster)
container_volume 43
creator Hueso-Gonzalez, F
Vijande, J
Ballester, F
Perez-Calatayud, J
Siebert, F
description Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).
doi_str_mv 10.1118/1.4956875
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_wiley_primary_10_1118_1_4956875_MP6875</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP6875</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1355-d9f5461bf0d77f342495ef1934b3bd63ded4759092886e3df016005e221550cd3</originalsourceid><addsrcrecordid>eNp9kM9O3DAQxq0KJBbogTew1FORTMf_kk1vkLaAtIjVbjlHXmfcdRWSlW2E8hy8cL1kr-U0I81vvvnmI-SCwxXnfP6NX6lKF_NSfyIzoUrJlIDqiMwAKsWEAn1CTmP8CwCF1DAjb-sndssEcAbiO73e7TpvTfJDTwdHV2Zcp4DJbqnvad35Pg87WpuIMcO56exLN-FuCPQOE4bhD_bo00jrIQS0-2Hcry9-rOgSw7PpsU_0nnGh6TIMMZmE9CYYux3TFoPZjefk2Jku4udDPSNPv37-ru_Y4vH2vr5eMMul1qytnFYF3zhoy9JJJfLn6Hgl1UZu2kK22KpSV1CJ-bxA2TrgBYBGIbjWYFt5Rr5MutmEb6L1Ce3WDn2fXTdCFKoSSmXq60TZbDYGdM0u-GcTxoZDs8-84c0h88yyiX31HY7_B5uH5YG_nPj98fccPxD_B6p5jJ4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Hueso-Gonzalez, F ; Vijande, J ; Ballester, F ; Perez-Calatayud, J ; Siebert, F</creator><creatorcontrib>Hueso-Gonzalez, F ; Vijande, J ; Ballester, F ; Perez-Calatayud, J ; Siebert, F</creatorcontrib><description>Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.4956875</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>60 APPLIED LIFE SCIENCES ; BRACHYTHERAPY ; CORRECTIONS ; Dosimetry ; Fellowships ; IODINE 125 ; Medical treatment planning ; MONTE CARLO METHOD ; Monte Carlo methods ; PROSTATE ; RADIATION PROTECTION AND DOSIMETRY ; Tissues ; Ultrasonography ; URINARY TRACT</subject><ispartof>Medical physics (Lancaster), 2016-06, Vol.43 (6), p.3623-3623</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2016 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.4956875$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>230,314,776,780,881,1411,27901,27902,45551</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/22649244$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Hueso-Gonzalez, F</creatorcontrib><creatorcontrib>Vijande, J</creatorcontrib><creatorcontrib>Ballester, F</creatorcontrib><creatorcontrib>Perez-Calatayud, J</creatorcontrib><creatorcontrib>Siebert, F</creatorcontrib><title>SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy</title><title>Medical physics (Lancaster)</title><description>Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).</description><subject>60 APPLIED LIFE SCIENCES</subject><subject>BRACHYTHERAPY</subject><subject>CORRECTIONS</subject><subject>Dosimetry</subject><subject>Fellowships</subject><subject>IODINE 125</subject><subject>Medical treatment planning</subject><subject>MONTE CARLO METHOD</subject><subject>Monte Carlo methods</subject><subject>PROSTATE</subject><subject>RADIATION PROTECTION AND DOSIMETRY</subject><subject>Tissues</subject><subject>Ultrasonography</subject><subject>URINARY TRACT</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp9kM9O3DAQxq0KJBbogTew1FORTMf_kk1vkLaAtIjVbjlHXmfcdRWSlW2E8hy8cL1kr-U0I81vvvnmI-SCwxXnfP6NX6lKF_NSfyIzoUrJlIDqiMwAKsWEAn1CTmP8CwCF1DAjb-sndssEcAbiO73e7TpvTfJDTwdHV2Zcp4DJbqnvad35Pg87WpuIMcO56exLN-FuCPQOE4bhD_bo00jrIQS0-2Hcry9-rOgSw7PpsU_0nnGh6TIMMZmE9CYYux3TFoPZjefk2Jku4udDPSNPv37-ru_Y4vH2vr5eMMul1qytnFYF3zhoy9JJJfLn6Hgl1UZu2kK22KpSV1CJ-bxA2TrgBYBGIbjWYFt5Rr5MutmEb6L1Ce3WDn2fXTdCFKoSSmXq60TZbDYGdM0u-GcTxoZDs8-84c0h88yyiX31HY7_B5uH5YG_nPj98fccPxD_B6p5jJ4</recordid><startdate>201606</startdate><enddate>201606</enddate><creator>Hueso-Gonzalez, F</creator><creator>Vijande, J</creator><creator>Ballester, F</creator><creator>Perez-Calatayud, J</creator><creator>Siebert, F</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>201606</creationdate><title>SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy</title><author>Hueso-Gonzalez, F ; Vijande, J ; Ballester, F ; Perez-Calatayud, J ; Siebert, F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1355-d9f5461bf0d77f342495ef1934b3bd63ded4759092886e3df016005e221550cd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>60 APPLIED LIFE SCIENCES</topic><topic>BRACHYTHERAPY</topic><topic>CORRECTIONS</topic><topic>Dosimetry</topic><topic>Fellowships</topic><topic>IODINE 125</topic><topic>Medical treatment planning</topic><topic>MONTE CARLO METHOD</topic><topic>Monte Carlo methods</topic><topic>PROSTATE</topic><topic>RADIATION PROTECTION AND DOSIMETRY</topic><topic>Tissues</topic><topic>Ultrasonography</topic><topic>URINARY TRACT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hueso-Gonzalez, F</creatorcontrib><creatorcontrib>Vijande, J</creatorcontrib><creatorcontrib>Ballester, F</creatorcontrib><creatorcontrib>Perez-Calatayud, J</creatorcontrib><creatorcontrib>Siebert, F</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hueso-Gonzalez, F</au><au>Vijande, J</au><au>Ballester, F</au><au>Perez-Calatayud, J</au><au>Siebert, F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy</atitle><jtitle>Medical physics (Lancaster)</jtitle><date>2016-06</date><risdate>2016</risdate><volume>43</volume><issue>6</issue><spage>3623</spage><epage>3623</epage><pages>3623-3623</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.4956875</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2016-06, Vol.43 (6), p.3623-3623
issn 0094-2405
2473-4209
language eng
recordid cdi_wiley_primary_10_1118_1_4956875_MP6875
source Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects 60 APPLIED LIFE SCIENCES
BRACHYTHERAPY
CORRECTIONS
Dosimetry
Fellowships
IODINE 125
Medical treatment planning
MONTE CARLO METHOD
Monte Carlo methods
PROSTATE
RADIATION PROTECTION AND DOSIMETRY
Tissues
Ultrasonography
URINARY TRACT
title SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T17%3A13%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU-G-201-02:%20Application%20of%20RayStretch%20in%20Clinical%20Cases:%20A%20Calculation%20for%20Heterogeneity%20Corrections%20in%20LDR%20Permanent%20I-125%20Prostate%20Brachytherapy&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Hueso-Gonzalez,%20F&rft.date=2016-06&rft.volume=43&rft.issue=6&rft.spage=3623&rft.epage=3623&rft.pages=3623-3623&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.4956875&rft_dat=%3Cwiley_cross%3EMP6875%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true