Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy
Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafrac...
Gespeichert in:
Veröffentlicht in: | Medical Physics 2008-07, Vol.35 (7), p.3407-3407 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3407 |
---|---|
container_issue | 7 |
container_start_page | 3407 |
container_title | Medical Physics |
container_volume | 35 |
creator | Strydhorst, JH Caudrelier, J‐M Montgomery, LA Clark, BG MacPherson, MS |
description | Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion. |
doi_str_mv | 10.1118/1.2965949 |
format | Article |
fullrecord | <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_wiley_primary_10_1118_1_2965949_MP5949</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1899790723</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2339-e943e259a8c138126d1ebabc3b52a8beb0808c1581760f46b7c5abb80f28f693</originalsourceid><addsrcrecordid>eNp9kE1OwzAQRi0EoqWw4ALIS0BKGdv5sdmhqkClIrroPrJThxoldbHTorDqEVhwwp6EQAo7WM1I8_S-0YfQKYE-IYRfkT4VcSRCsYe6NExYEFIQ-6gLIMKAhhB10JH3zwAQswgOUYfyiFAOSRepifWVdni7-cDT-cp5PFzr7eadwTUeLdbaV-ZJVsYusM2xxMtm14sKm7K0yhTmrb35upGUOLcOK6elr3BlS1vNtZPL-hgd5LLw-mQ3e2h6O5wO7oPx491ocDMOMsqYCLQImaaRkDwjjBMaz4hWUmVMRVRypRVwaE4RJ0kMeRirJIukUhxyyvNYsB46b7VLZ19WzeNpaXymi0IutF35lHAhEgFJE9ZDFy2aOeu903m6dKaUrk4JpF-NpiTdNdqwZzvtSpV69kv-VNgAQQu8mkLXf5vSh8lOeNnyPjPVd33_pH8CEKeNgg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1899790723</pqid></control><display><type>article</type><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><source>Wiley-Blackwell Journals</source><source>Alma/SFX Local Collection</source><creator>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</creator><creatorcontrib>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</creatorcontrib><description>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.2965949</identifier><identifier>PMID: 28512807</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>Cancer ; Cardiac dynamics ; Drug delivery ; Heart ; Radiation therapy ; Radiation treatment</subject><ispartof>Medical Physics, 2008-07, Vol.35 (7), p.3407-3407</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.2965949$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>310,311,315,781,785,790,791,1418,23935,23936,25145,27929,27930,45580</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28512807$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Strydhorst, JH</creatorcontrib><creatorcontrib>Caudrelier, J‐M</creatorcontrib><creatorcontrib>Montgomery, LA</creatorcontrib><creatorcontrib>Clark, BG</creatorcontrib><creatorcontrib>MacPherson, MS</creatorcontrib><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><title>Medical Physics</title><addtitle>Med Phys</addtitle><description>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</description><subject>Cancer</subject><subject>Cardiac dynamics</subject><subject>Drug delivery</subject><subject>Heart</subject><subject>Radiation therapy</subject><subject>Radiation treatment</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp9kE1OwzAQRi0EoqWw4ALIS0BKGdv5sdmhqkClIrroPrJThxoldbHTorDqEVhwwp6EQAo7WM1I8_S-0YfQKYE-IYRfkT4VcSRCsYe6NExYEFIQ-6gLIMKAhhB10JH3zwAQswgOUYfyiFAOSRepifWVdni7-cDT-cp5PFzr7eadwTUeLdbaV-ZJVsYusM2xxMtm14sKm7K0yhTmrb35upGUOLcOK6elr3BlS1vNtZPL-hgd5LLw-mQ3e2h6O5wO7oPx491ocDMOMsqYCLQImaaRkDwjjBMaz4hWUmVMRVRypRVwaE4RJ0kMeRirJIukUhxyyvNYsB46b7VLZ19WzeNpaXymi0IutF35lHAhEgFJE9ZDFy2aOeu903m6dKaUrk4JpF-NpiTdNdqwZzvtSpV69kv-VNgAQQu8mkLXf5vSh8lOeNnyPjPVd33_pH8CEKeNgg</recordid><startdate>200807</startdate><enddate>200807</enddate><creator>Strydhorst, JH</creator><creator>Caudrelier, J‐M</creator><creator>Montgomery, LA</creator><creator>Clark, BG</creator><creator>MacPherson, MS</creator><general>American Association of Physicists in Medicine</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200807</creationdate><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><author>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2339-e943e259a8c138126d1ebabc3b52a8beb0808c1581760f46b7c5abb80f28f693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Cancer</topic><topic>Cardiac dynamics</topic><topic>Drug delivery</topic><topic>Heart</topic><topic>Radiation therapy</topic><topic>Radiation treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Strydhorst, JH</creatorcontrib><creatorcontrib>Caudrelier, J‐M</creatorcontrib><creatorcontrib>Montgomery, LA</creatorcontrib><creatorcontrib>Clark, BG</creatorcontrib><creatorcontrib>MacPherson, MS</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Strydhorst, JH</au><au>Caudrelier, J‐M</au><au>Montgomery, LA</au><au>Clark, BG</au><au>MacPherson, MS</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</atitle><jtitle>Medical Physics</jtitle><addtitle>Med Phys</addtitle><date>2008-07</date><risdate>2008</risdate><volume>35</volume><issue>7</issue><spage>3407</spage><epage>3407</epage><pages>3407-3407</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><pmid>28512807</pmid><doi>10.1118/1.2965949</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-2405 |
ispartof | Medical Physics, 2008-07, Vol.35 (7), p.3407-3407 |
issn | 0094-2405 2473-4209 |
language | eng |
recordid | cdi_wiley_primary_10_1118_1_2965949_MP5949 |
source | Wiley-Blackwell Journals; Alma/SFX Local Collection |
subjects | Cancer Cardiac dynamics Drug delivery Heart Radiation therapy Radiation treatment |
title | Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-13T21%3A54%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Poster%20%E2%80%94%20Thurs%20Eve%E2%80%9030:%20Investigation%20of%20a%20patient%20immobilization%20system%20for%20breast%20tomotherapy&rft.jtitle=Medical%20Physics&rft.au=Strydhorst,%20JH&rft.date=2008-07&rft.volume=35&rft.issue=7&rft.spage=3407&rft.epage=3407&rft.pages=3407-3407&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.2965949&rft_dat=%3Cproquest_wiley%3E1899790723%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1899790723&rft_id=info:pmid/28512807&rfr_iscdi=true |