Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy

Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafrac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2008-07, Vol.35 (7), p.3407-3407
Hauptverfasser: Strydhorst, JH, Caudrelier, J‐M, Montgomery, LA, Clark, BG, MacPherson, MS
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3407
container_issue 7
container_start_page 3407
container_title Medical Physics
container_volume 35
creator Strydhorst, JH
Caudrelier, J‐M
Montgomery, LA
Clark, BG
MacPherson, MS
description Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.
doi_str_mv 10.1118/1.2965949
format Article
fullrecord <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_wiley_primary_10_1118_1_2965949_MP5949</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1899790723</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2339-e943e259a8c138126d1ebabc3b52a8beb0808c1581760f46b7c5abb80f28f693</originalsourceid><addsrcrecordid>eNp9kE1OwzAQRi0EoqWw4ALIS0BKGdv5sdmhqkClIrroPrJThxoldbHTorDqEVhwwp6EQAo7WM1I8_S-0YfQKYE-IYRfkT4VcSRCsYe6NExYEFIQ-6gLIMKAhhB10JH3zwAQswgOUYfyiFAOSRepifWVdni7-cDT-cp5PFzr7eadwTUeLdbaV-ZJVsYusM2xxMtm14sKm7K0yhTmrb35upGUOLcOK6elr3BlS1vNtZPL-hgd5LLw-mQ3e2h6O5wO7oPx491ocDMOMsqYCLQImaaRkDwjjBMaz4hWUmVMRVRypRVwaE4RJ0kMeRirJIukUhxyyvNYsB46b7VLZ19WzeNpaXymi0IutF35lHAhEgFJE9ZDFy2aOeu903m6dKaUrk4JpF-NpiTdNdqwZzvtSpV69kv-VNgAQQu8mkLXf5vSh8lOeNnyPjPVd33_pH8CEKeNgg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1899790723</pqid></control><display><type>article</type><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><source>Wiley-Blackwell Journals</source><source>Alma/SFX Local Collection</source><creator>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</creator><creatorcontrib>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</creatorcontrib><description>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.2965949</identifier><identifier>PMID: 28512807</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>Cancer ; Cardiac dynamics ; Drug delivery ; Heart ; Radiation therapy ; Radiation treatment</subject><ispartof>Medical Physics, 2008-07, Vol.35 (7), p.3407-3407</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.2965949$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>310,311,315,781,785,790,791,1418,23935,23936,25145,27929,27930,45580</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28512807$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Strydhorst, JH</creatorcontrib><creatorcontrib>Caudrelier, J‐M</creatorcontrib><creatorcontrib>Montgomery, LA</creatorcontrib><creatorcontrib>Clark, BG</creatorcontrib><creatorcontrib>MacPherson, MS</creatorcontrib><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><title>Medical Physics</title><addtitle>Med Phys</addtitle><description>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</description><subject>Cancer</subject><subject>Cardiac dynamics</subject><subject>Drug delivery</subject><subject>Heart</subject><subject>Radiation therapy</subject><subject>Radiation treatment</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp9kE1OwzAQRi0EoqWw4ALIS0BKGdv5sdmhqkClIrroPrJThxoldbHTorDqEVhwwp6EQAo7WM1I8_S-0YfQKYE-IYRfkT4VcSRCsYe6NExYEFIQ-6gLIMKAhhB10JH3zwAQswgOUYfyiFAOSRepifWVdni7-cDT-cp5PFzr7eadwTUeLdbaV-ZJVsYusM2xxMtm14sKm7K0yhTmrb35upGUOLcOK6elr3BlS1vNtZPL-hgd5LLw-mQ3e2h6O5wO7oPx491ocDMOMsqYCLQImaaRkDwjjBMaz4hWUmVMRVRypRVwaE4RJ0kMeRirJIukUhxyyvNYsB46b7VLZ19WzeNpaXymi0IutF35lHAhEgFJE9ZDFy2aOeu903m6dKaUrk4JpF-NpiTdNdqwZzvtSpV69kv-VNgAQQu8mkLXf5vSh8lOeNnyPjPVd33_pH8CEKeNgg</recordid><startdate>200807</startdate><enddate>200807</enddate><creator>Strydhorst, JH</creator><creator>Caudrelier, J‐M</creator><creator>Montgomery, LA</creator><creator>Clark, BG</creator><creator>MacPherson, MS</creator><general>American Association of Physicists in Medicine</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200807</creationdate><title>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</title><author>Strydhorst, JH ; Caudrelier, J‐M ; Montgomery, LA ; Clark, BG ; MacPherson, MS</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2339-e943e259a8c138126d1ebabc3b52a8beb0808c1581760f46b7c5abb80f28f693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Cancer</topic><topic>Cardiac dynamics</topic><topic>Drug delivery</topic><topic>Heart</topic><topic>Radiation therapy</topic><topic>Radiation treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Strydhorst, JH</creatorcontrib><creatorcontrib>Caudrelier, J‐M</creatorcontrib><creatorcontrib>Montgomery, LA</creatorcontrib><creatorcontrib>Clark, BG</creatorcontrib><creatorcontrib>MacPherson, MS</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Strydhorst, JH</au><au>Caudrelier, J‐M</au><au>Montgomery, LA</au><au>Clark, BG</au><au>MacPherson, MS</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy</atitle><jtitle>Medical Physics</jtitle><addtitle>Med Phys</addtitle><date>2008-07</date><risdate>2008</risdate><volume>35</volume><issue>7</issue><spage>3407</spage><epage>3407</epage><pages>3407-3407</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Using tomotherapy to deliver adjuvant radiation therapy for breast cancer treatment requires more precise immobilization than can be achieved using gravity alone. We evaluated the use of a thermoplastic shell to immobilize the patient's torso during breast cancer treatment. To measure intrafraction breathing motion, 4DCT scans were performed for eight post‐lumpectomy or post‐mastectomy breast cancer patients with the thermoplastic shell in place. The 4DCT scans were then analyzed to determine the magnitude of motion of the breast surface, chest wall, and heart over the breathing cycle. Maximum surface motion was typically less than 2mm, with a maximum of 4mm. Maximum displacement of the chest wall was less than 3mm with a maximum of 5mm in a single patient. Comparison with the setup errors recorded prior to repositioning the patients suggests that, with the thermoplastic shell in place, patient setup error will be a more significant source of uncertainty in patient position than breathing motion.</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><pmid>28512807</pmid><doi>10.1118/1.2965949</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2008-07, Vol.35 (7), p.3407-3407
issn 0094-2405
2473-4209
language eng
recordid cdi_wiley_primary_10_1118_1_2965949_MP5949
source Wiley-Blackwell Journals; Alma/SFX Local Collection
subjects Cancer
Cardiac dynamics
Drug delivery
Heart
Radiation therapy
Radiation treatment
title Poster — Thurs Eve‐30: Investigation of a patient immobilization system for breast tomotherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-13T21%3A54%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Poster%20%E2%80%94%20Thurs%20Eve%E2%80%9030:%20Investigation%20of%20a%20patient%20immobilization%20system%20for%20breast%20tomotherapy&rft.jtitle=Medical%20Physics&rft.au=Strydhorst,%20JH&rft.date=2008-07&rft.volume=35&rft.issue=7&rft.spage=3407&rft.epage=3407&rft.pages=3407-3407&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.2965949&rft_dat=%3Cproquest_wiley%3E1899790723%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1899790723&rft_id=info:pmid/28512807&rfr_iscdi=true