Realistic CT simulation using the 4D XCAT phantom

The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate repr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2008-08, Vol.35 (8), p.3800-3808
Hauptverfasser: Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., Tsui, B. M. W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3808
container_issue 8
container_start_page 3800
container_title Medical physics (Lancaster)
container_volume 35
creator Segars, W. P.
Mahesh, M.
Beck, T. J.
Frey, E. C.
Tsui, B. M. W.
description The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude that the efficient XCAT-based CT simulator developed in this work will have applications in a broad range of CT imaging research.
doi_str_mv 10.1118/1.2955743
format Article
fullrecord <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_wiley_primary_10_1118_1_2955743_MP5743</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69525854</sourcerecordid><originalsourceid>FETCH-LOGICAL-c6023-953e05169c9d0882053d087ced5f7a89460919c0db7711527024990feb8123103</originalsourceid><addsrcrecordid>eNp9kUtLxDAQx4Mouj4OfgHpSVDoOnk1zUVY6hMURVbwFrJpuhvpY23aFb-91S0-kPU0h_zmN5n_ILSPYYgxjk_wkEjOBaNraECYoCEjINfRAECykDDgW2jb-2cAiCiHTbSFYyGEpHKA8IPVufONM0EyDrwr2lw3riqD1rtyGjQzG7Cz4CkZjYP5TJdNVeyijUzn3u71dQc9XpyPk6vw5u7yOhndhCYCQkPJqQWOI2lkCnFMgNOuCmNTngkdSxaBxNJAOhECY04EECYlZHYSY0Ix0B10uvTO20lhU2PLpta5mteu0PWbqrRTv19KN1PTaqFIDLJTdoLDXlBXL631jSqcNzbPdWmr1qtIcsJjzjrwaAmauvK-ttnXEAzqI2CFVR9wxx78_NU32SfaAeESeHW5fVttUrf3vbBf0xvXfEa_uufrVioZq_5WneB4lWBR1T8GztPsP_jvru9ml7In</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69525854</pqid></control><display><type>article</type><title>Realistic CT simulation using the 4D XCAT phantom</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Segars, W. P. ; Mahesh, M. ; Beck, T. J. ; Frey, E. C. ; Tsui, B. M. W.</creator><creatorcontrib>Segars, W. P. ; Mahesh, M. ; Beck, T. J. ; Frey, E. C. ; Tsui, B. M. W.</creatorcontrib><description>The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude that the efficient XCAT-based CT simulator developed in this work will have applications in a broad range of CT imaging research.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>EISSN: 0094-2405</identifier><identifier>DOI: 10.1118/1.2955743</identifier><identifier>PMID: 18777939</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>Algorithms ; Anatomy ; Biomedical modeling ; Computed tomography ; computer graphics ; computer phantom ; Computer Simulation ; computerised tomography ; Female ; Heart ; Humans ; Image Processing, Computer-Assisted - methods ; image reconstruction ; Male ; medical image processing ; Medical image quality ; Medical image reconstruction ; Medical imaging ; medical imaging simulation ; Medical X‐ray imaging ; Models, Biological ; Myocardium - pathology ; phantoms ; Phantoms, Imaging ; Radiation Imaging Physics ; ray tracing ; Reconstruction ; Respiratory Mechanics ; Time Factors ; Tomography, X-Ray Computed - methods ; Wave fronts and ray tracing ; Whole-Body Irradiation ; x-ray CT</subject><ispartof>Medical physics (Lancaster), 2008-08, Vol.35 (8), p.3800-3808</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine</rights><rights>Copyright © 2008 American Association of Physicists in Medicine 2008 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c6023-953e05169c9d0882053d087ced5f7a89460919c0db7711527024990feb8123103</citedby><cites>FETCH-LOGICAL-c6023-953e05169c9d0882053d087ced5f7a89460919c0db7711527024990feb8123103</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1118%2F1.2955743$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.2955743$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>230,314,776,780,881,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18777939$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Segars, W. P.</creatorcontrib><creatorcontrib>Mahesh, M.</creatorcontrib><creatorcontrib>Beck, T. J.</creatorcontrib><creatorcontrib>Frey, E. C.</creatorcontrib><creatorcontrib>Tsui, B. M. W.</creatorcontrib><title>Realistic CT simulation using the 4D XCAT phantom</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><description>The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude that the efficient XCAT-based CT simulator developed in this work will have applications in a broad range of CT imaging research.</description><subject>Algorithms</subject><subject>Anatomy</subject><subject>Biomedical modeling</subject><subject>Computed tomography</subject><subject>computer graphics</subject><subject>computer phantom</subject><subject>Computer Simulation</subject><subject>computerised tomography</subject><subject>Female</subject><subject>Heart</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>image reconstruction</subject><subject>Male</subject><subject>medical image processing</subject><subject>Medical image quality</subject><subject>Medical image reconstruction</subject><subject>Medical imaging</subject><subject>medical imaging simulation</subject><subject>Medical X‐ray imaging</subject><subject>Models, Biological</subject><subject>Myocardium - pathology</subject><subject>phantoms</subject><subject>Phantoms, Imaging</subject><subject>Radiation Imaging Physics</subject><subject>ray tracing</subject><subject>Reconstruction</subject><subject>Respiratory Mechanics</subject><subject>Time Factors</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Wave fronts and ray tracing</subject><subject>Whole-Body Irradiation</subject><subject>x-ray CT</subject><issn>0094-2405</issn><issn>2473-4209</issn><issn>0094-2405</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kUtLxDAQx4Mouj4OfgHpSVDoOnk1zUVY6hMURVbwFrJpuhvpY23aFb-91S0-kPU0h_zmN5n_ILSPYYgxjk_wkEjOBaNraECYoCEjINfRAECykDDgW2jb-2cAiCiHTbSFYyGEpHKA8IPVufONM0EyDrwr2lw3riqD1rtyGjQzG7Cz4CkZjYP5TJdNVeyijUzn3u71dQc9XpyPk6vw5u7yOhndhCYCQkPJqQWOI2lkCnFMgNOuCmNTngkdSxaBxNJAOhECY04EECYlZHYSY0Ix0B10uvTO20lhU2PLpta5mteu0PWbqrRTv19KN1PTaqFIDLJTdoLDXlBXL631jSqcNzbPdWmr1qtIcsJjzjrwaAmauvK-ttnXEAzqI2CFVR9wxx78_NU32SfaAeESeHW5fVttUrf3vbBf0xvXfEa_uufrVioZq_5WneB4lWBR1T8GztPsP_jvru9ml7In</recordid><startdate>200808</startdate><enddate>200808</enddate><creator>Segars, W. P.</creator><creator>Mahesh, M.</creator><creator>Beck, T. J.</creator><creator>Frey, E. C.</creator><creator>Tsui, B. M. W.</creator><general>American Association of Physicists in Medicine</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>200808</creationdate><title>Realistic CT simulation using the 4D XCAT phantom</title><author>Segars, W. P. ; Mahesh, M. ; Beck, T. J. ; Frey, E. C. ; Tsui, B. M. W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c6023-953e05169c9d0882053d087ced5f7a89460919c0db7711527024990feb8123103</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Algorithms</topic><topic>Anatomy</topic><topic>Biomedical modeling</topic><topic>Computed tomography</topic><topic>computer graphics</topic><topic>computer phantom</topic><topic>Computer Simulation</topic><topic>computerised tomography</topic><topic>Female</topic><topic>Heart</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>image reconstruction</topic><topic>Male</topic><topic>medical image processing</topic><topic>Medical image quality</topic><topic>Medical image reconstruction</topic><topic>Medical imaging</topic><topic>medical imaging simulation</topic><topic>Medical X‐ray imaging</topic><topic>Models, Biological</topic><topic>Myocardium - pathology</topic><topic>phantoms</topic><topic>Phantoms, Imaging</topic><topic>Radiation Imaging Physics</topic><topic>ray tracing</topic><topic>Reconstruction</topic><topic>Respiratory Mechanics</topic><topic>Time Factors</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Wave fronts and ray tracing</topic><topic>Whole-Body Irradiation</topic><topic>x-ray CT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Segars, W. P.</creatorcontrib><creatorcontrib>Mahesh, M.</creatorcontrib><creatorcontrib>Beck, T. J.</creatorcontrib><creatorcontrib>Frey, E. C.</creatorcontrib><creatorcontrib>Tsui, B. M. W.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Segars, W. P.</au><au>Mahesh, M.</au><au>Beck, T. J.</au><au>Frey, E. C.</au><au>Tsui, B. M. W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Realistic CT simulation using the 4D XCAT phantom</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2008-08</date><risdate>2008</risdate><volume>35</volume><issue>8</issue><spage>3800</spage><epage>3808</epage><pages>3800-3808</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><eissn>0094-2405</eissn><coden>MPHYA6</coden><abstract>The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude that the efficient XCAT-based CT simulator developed in this work will have applications in a broad range of CT imaging research.</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><pmid>18777939</pmid><doi>10.1118/1.2955743</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2008-08, Vol.35 (8), p.3800-3808
issn 0094-2405
2473-4209
0094-2405
language eng
recordid cdi_wiley_primary_10_1118_1_2955743_MP5743
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Algorithms
Anatomy
Biomedical modeling
Computed tomography
computer graphics
computer phantom
Computer Simulation
computerised tomography
Female
Heart
Humans
Image Processing, Computer-Assisted - methods
image reconstruction
Male
medical image processing
Medical image quality
Medical image reconstruction
Medical imaging
medical imaging simulation
Medical X‐ray imaging
Models, Biological
Myocardium - pathology
phantoms
Phantoms, Imaging
Radiation Imaging Physics
ray tracing
Reconstruction
Respiratory Mechanics
Time Factors
Tomography, X-Ray Computed - methods
Wave fronts and ray tracing
Whole-Body Irradiation
x-ray CT
title Realistic CT simulation using the 4D XCAT phantom
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T10%3A45%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Realistic%20CT%20simulation%20using%20the%204D%20XCAT%20phantom&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Segars,%20W.%20P.&rft.date=2008-08&rft.volume=35&rft.issue=8&rft.spage=3800&rft.epage=3808&rft.pages=3800-3808&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.2955743&rft_dat=%3Cproquest_wiley%3E69525854%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=69525854&rft_id=info:pmid/18777939&rfr_iscdi=true