Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign

A chemical ionization mass spectrometer (CIMS) was used for rapid detection of HNO3 in air traffic corridors, primarily over the North Atlantic region, during the NASA Subsonic Assessment Ozone and Nitrogen Oxide Experiment (SONEX) campaign in the fall of 1997. The sensitivity of the CIMS instrument...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Geophysical Research: Atmospheres 2000-02, Vol.105 (D3), p.3701-3707
Hauptverfasser: Miller, Thomas M., Ballenthin, John O., Meads, Roger F., Hunton, Donald E., Thorn, Willard F., Viggiano, A. A., Kondo, Yutaka, Koike, Makoto, Zhao, Yongjing
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3707
container_issue D3
container_start_page 3701
container_title Journal of Geophysical Research: Atmospheres
container_volume 105
creator Miller, Thomas M.
Ballenthin, John O.
Meads, Roger F.
Hunton, Donald E.
Thorn, Willard F.
Viggiano, A. A.
Kondo, Yutaka
Koike, Makoto
Zhao, Yongjing
description A chemical ionization mass spectrometer (CIMS) was used for rapid detection of HNO3 in air traffic corridors, primarily over the North Atlantic region, during the NASA Subsonic Assessment Ozone and Nitrogen Oxide Experiment (SONEX) campaign in the fall of 1997. The sensitivity of the CIMS instrument approaches 1 ion count per second for each 106 molecules cm−3, under ideal conditions. During the SONEX mission the precision of the experiment was considerably lower due to inlet fluctuations. Ten‐second integration periods were used to obtain a precision of typically 10 parts per trillion by volume. A description is given of the instrument and the technique, including inflight calibration using a permeation tube. Comparisons are made with NOy data and with the University of New Hampshire HNO3 data obtained with a mist chamber method.
doi_str_mv 10.1029/1999JD900443
format Article
fullrecord <record><control><sourceid>istex_wiley</sourceid><recordid>TN_cdi_wiley_primary_10_1029_1999JD900443_JGRD7088</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_TQGCNCNG_5</sourcerecordid><originalsourceid>FETCH-LOGICAL-i2348-a086e630570c2fed627f95e22b70770c9926a7c3dafb7284954d4802ef0bc583</originalsourceid><addsrcrecordid>eNpNkE1OwzAQhS0EElXpjgP4AoGJ8-N4idLSUlWtgEqwi1xn3BqaH-xEUC7CdUkoQszmzczT96QZQi59uPKBiWtfCDEfC4AwDE7IgPlR7DEG7JQMwA8TDxjj52Tk3At0FUZxCP6AfKU7LIySe2qq0nzKphNaSOeoq1E1tiqwQUsbVLvSvLVIddVNO6QFStdaLLBsaKXpbLkKqCmpNJ1tpdZGUVVZa_LKut7ombau-yxb1ZWrd2iR5q015fbHfFwtJ89UyaKWZltekDMt9w5Hvzok69vJOp15i9X0Lr1ZeIYF3VESkhjjACIOimnMY8a1iJCxDQfe7YRgseQqyKXecJaEIgrzMAGGGjYqSoIhYcfYd7PHQ1ZbU0h7yHzI-p9m_3-azacPYw5JD3lHyLgGP_4gaV-zmAc8yp6W02x9P02XaddEwTchLXyk</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Wiley Online Library Free Content</source><source>Wiley-Blackwell AGU Digital Library</source><source>Alma/SFX Local Collection</source><creator>Miller, Thomas M. ; Ballenthin, John O. ; Meads, Roger F. ; Hunton, Donald E. ; Thorn, Willard F. ; Viggiano, A. A. ; Kondo, Yutaka ; Koike, Makoto ; Zhao, Yongjing</creator><creatorcontrib>Miller, Thomas M. ; Ballenthin, John O. ; Meads, Roger F. ; Hunton, Donald E. ; Thorn, Willard F. ; Viggiano, A. A. ; Kondo, Yutaka ; Koike, Makoto ; Zhao, Yongjing</creatorcontrib><description>A chemical ionization mass spectrometer (CIMS) was used for rapid detection of HNO3 in air traffic corridors, primarily over the North Atlantic region, during the NASA Subsonic Assessment Ozone and Nitrogen Oxide Experiment (SONEX) campaign in the fall of 1997. The sensitivity of the CIMS instrument approaches 1 ion count per second for each 106 molecules cm−3, under ideal conditions. During the SONEX mission the precision of the experiment was considerably lower due to inlet fluctuations. Ten‐second integration periods were used to obtain a precision of typically 10 parts per trillion by volume. A description is given of the instrument and the technique, including inflight calibration using a permeation tube. Comparisons are made with NOy data and with the University of New Hampshire HNO3 data obtained with a mist chamber method.</description><identifier>ISSN: 0148-0227</identifier><identifier>EISSN: 2156-2202</identifier><identifier>DOI: 10.1029/1999JD900443</identifier><language>eng</language><publisher>Blackwell Publishing Ltd</publisher><ispartof>Journal of Geophysical Research: Atmospheres, 2000-02, Vol.105 (D3), p.3701-3707</ispartof><rights>Copyright 2000 by the American Geophysical Union.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1029%2F1999JD900443$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1029%2F1999JD900443$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,1427,11494,27903,27904,45553,45554,46387,46446,46811,46870</link.rule.ids></links><search><creatorcontrib>Miller, Thomas M.</creatorcontrib><creatorcontrib>Ballenthin, John O.</creatorcontrib><creatorcontrib>Meads, Roger F.</creatorcontrib><creatorcontrib>Hunton, Donald E.</creatorcontrib><creatorcontrib>Thorn, Willard F.</creatorcontrib><creatorcontrib>Viggiano, A. A.</creatorcontrib><creatorcontrib>Kondo, Yutaka</creatorcontrib><creatorcontrib>Koike, Makoto</creatorcontrib><creatorcontrib>Zhao, Yongjing</creatorcontrib><title>Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign</title><title>Journal of Geophysical Research: Atmospheres</title><addtitle>J. Geophys. Res</addtitle><description>A chemical ionization mass spectrometer (CIMS) was used for rapid detection of HNO3 in air traffic corridors, primarily over the North Atlantic region, during the NASA Subsonic Assessment Ozone and Nitrogen Oxide Experiment (SONEX) campaign in the fall of 1997. The sensitivity of the CIMS instrument approaches 1 ion count per second for each 106 molecules cm−3, under ideal conditions. During the SONEX mission the precision of the experiment was considerably lower due to inlet fluctuations. Ten‐second integration periods were used to obtain a precision of typically 10 parts per trillion by volume. A description is given of the instrument and the technique, including inflight calibration using a permeation tube. Comparisons are made with NOy data and with the University of New Hampshire HNO3 data obtained with a mist chamber method.</description><issn>0148-0227</issn><issn>2156-2202</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNpNkE1OwzAQhS0EElXpjgP4AoGJ8-N4idLSUlWtgEqwi1xn3BqaH-xEUC7CdUkoQszmzczT96QZQi59uPKBiWtfCDEfC4AwDE7IgPlR7DEG7JQMwA8TDxjj52Tk3At0FUZxCP6AfKU7LIySe2qq0nzKphNaSOeoq1E1tiqwQUsbVLvSvLVIddVNO6QFStdaLLBsaKXpbLkKqCmpNJ1tpdZGUVVZa_LKut7ombau-yxb1ZWrd2iR5q015fbHfFwtJ89UyaKWZltekDMt9w5Hvzok69vJOp15i9X0Lr1ZeIYF3VESkhjjACIOimnMY8a1iJCxDQfe7YRgseQqyKXecJaEIgrzMAGGGjYqSoIhYcfYd7PHQ1ZbU0h7yHzI-p9m_3-azacPYw5JD3lHyLgGP_4gaV-zmAc8yp6W02x9P02XaddEwTchLXyk</recordid><startdate>20000216</startdate><enddate>20000216</enddate><creator>Miller, Thomas M.</creator><creator>Ballenthin, John O.</creator><creator>Meads, Roger F.</creator><creator>Hunton, Donald E.</creator><creator>Thorn, Willard F.</creator><creator>Viggiano, A. A.</creator><creator>Kondo, Yutaka</creator><creator>Koike, Makoto</creator><creator>Zhao, Yongjing</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope></search><sort><creationdate>20000216</creationdate><title>Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign</title><author>Miller, Thomas M. ; Ballenthin, John O. ; Meads, Roger F. ; Hunton, Donald E. ; Thorn, Willard F. ; Viggiano, A. A. ; Kondo, Yutaka ; Koike, Makoto ; Zhao, Yongjing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i2348-a086e630570c2fed627f95e22b70770c9926a7c3dafb7284954d4802ef0bc583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miller, Thomas M.</creatorcontrib><creatorcontrib>Ballenthin, John O.</creatorcontrib><creatorcontrib>Meads, Roger F.</creatorcontrib><creatorcontrib>Hunton, Donald E.</creatorcontrib><creatorcontrib>Thorn, Willard F.</creatorcontrib><creatorcontrib>Viggiano, A. A.</creatorcontrib><creatorcontrib>Kondo, Yutaka</creatorcontrib><creatorcontrib>Koike, Makoto</creatorcontrib><creatorcontrib>Zhao, Yongjing</creatorcontrib><collection>Istex</collection><jtitle>Journal of Geophysical Research: Atmospheres</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miller, Thomas M.</au><au>Ballenthin, John O.</au><au>Meads, Roger F.</au><au>Hunton, Donald E.</au><au>Thorn, Willard F.</au><au>Viggiano, A. A.</au><au>Kondo, Yutaka</au><au>Koike, Makoto</au><au>Zhao, Yongjing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign</atitle><jtitle>Journal of Geophysical Research: Atmospheres</jtitle><addtitle>J. Geophys. Res</addtitle><date>2000-02-16</date><risdate>2000</risdate><volume>105</volume><issue>D3</issue><spage>3701</spage><epage>3707</epage><pages>3701-3707</pages><issn>0148-0227</issn><eissn>2156-2202</eissn><abstract>A chemical ionization mass spectrometer (CIMS) was used for rapid detection of HNO3 in air traffic corridors, primarily over the North Atlantic region, during the NASA Subsonic Assessment Ozone and Nitrogen Oxide Experiment (SONEX) campaign in the fall of 1997. The sensitivity of the CIMS instrument approaches 1 ion count per second for each 106 molecules cm−3, under ideal conditions. During the SONEX mission the precision of the experiment was considerably lower due to inlet fluctuations. Ten‐second integration periods were used to obtain a precision of typically 10 parts per trillion by volume. A description is given of the instrument and the technique, including inflight calibration using a permeation tube. Comparisons are made with NOy data and with the University of New Hampshire HNO3 data obtained with a mist chamber method.</abstract><pub>Blackwell Publishing Ltd</pub><doi>10.1029/1999JD900443</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0148-0227
ispartof Journal of Geophysical Research: Atmospheres, 2000-02, Vol.105 (D3), p.3701-3707
issn 0148-0227
2156-2202
language eng
recordid cdi_wiley_primary_10_1029_1999JD900443_JGRD7088
source Wiley Online Library Journals Frontfile Complete; Wiley Online Library Free Content; Wiley-Blackwell AGU Digital Library; Alma/SFX Local Collection
title Chemical ionization mass spectrometer technique for the measurement of HNO3 in air traffic corridors in the upper troposphere during the SONEX campaign
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T07%3A54%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Chemical%20ionization%20mass%20spectrometer%20technique%20for%20the%20measurement%20of%20HNO3%20in%20air%20traffic%20corridors%20in%20the%20upper%20troposphere%20during%20the%20SONEX%20campaign&rft.jtitle=Journal%20of%20Geophysical%20Research:%20Atmospheres&rft.au=Miller,%20Thomas%20M.&rft.date=2000-02-16&rft.volume=105&rft.issue=D3&rft.spage=3701&rft.epage=3707&rft.pages=3701-3707&rft.issn=0148-0227&rft.eissn=2156-2202&rft_id=info:doi/10.1029/1999JD900443&rft_dat=%3Cistex_wiley%3Eark_67375_WNG_TQGCNCNG_5%3C/istex_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true