Local Area Conventional Protection
Higher demand is putting stress on the reliability, rapidity and sensitivity of local area conventional protection. This chapter introduces an improved scheme for transformer differential protection and new protection schemes different from differential protection. In the chapter, voltage and curren...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Buchkapitel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 173 |
---|---|
container_issue | |
container_start_page | 17 |
container_title | |
container_volume | |
creator | Ma, Jing Wang, Zengping |
description | Higher demand is putting stress on the reliability, rapidity and sensitivity of local area conventional protection. This chapter introduces an improved scheme for transformer differential protection and new protection schemes different from differential protection. In the chapter, voltage and current information are comprehensively utilized and a few new transformer protection schemes are constructed based on equivalent instantaneous leakage inductance and generalized instantaneous power. These schemes can efficiently solve the problems of lack of sensitivity when no‐load switching at faults and malfunction in the case of TA saturation due to external fault. With regard to transformer protection, the demand for high reliability and rapid response are on the increase, with larger capacity transformers constantly being brought into operation. The chapter further introduces a new location method for multiple inter‐line and grounded faults of double‐circuit transmission lines based on compensation voltage. |
doi_str_mv | 10.1002/9781119304814.ch2 |
format | Book Chapter |
fullrecord | <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_wiley_ebooks_10_1002_9781119304814_ch2_ch2</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8410143</ieee_id><sourcerecordid>EBC5333085_28_35</sourcerecordid><originalsourceid>FETCH-LOGICAL-i1032-166aa3765fe290b0fa72a03380495ecbcc39bf35139bc8bcf3bf3b5a69992cc63</originalsourceid><addsrcrecordid>eNpVkEFLxDAQhSOiqGt_wN4W77vOZJo2OS5FV2FBD3oOSZiyxdKsbVX892aplx6Gxxv45vFGiCXCBgHkvSk1IhqCXGO-CQd5JrLZ7nzmobwUNwgEGgtV6iuRDUPjgVDnipS5Fnf7GFy72vbsVlXsvrkbm9ilzWsfRw4ncysuatcOnP3rQrw_PrxVT-v9y-652u7XTQqQaywK56gsVM3SgIfaldIBkYbcKA4-BDK-JoVJgvahpuS8coUxRoZQ0ELgdPenafnXso_xY7AI9lTczkraVPw0iZETc-zj5xcP44SFVKN3bTi448j9YBVReoGyUltSCVpOUMPMdorROQLmRH_URGFx</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>book_chapter</recordtype><pqid>EBC5333085_28_35</pqid></control><display><type>book_chapter</type><title>Local Area Conventional Protection</title><source>Alma/SFX Local Collection</source><creator>Ma, Jing ; Wang, Zengping</creator><contributor>Ma, Jing ; Wang, Zengping</contributor><creatorcontrib>Ma, Jing ; Wang, Zengping ; Ma, Jing ; Wang, Zengping</creatorcontrib><description>Higher demand is putting stress on the reliability, rapidity and sensitivity of local area conventional protection. This chapter introduces an improved scheme for transformer differential protection and new protection schemes different from differential protection. In the chapter, voltage and current information are comprehensively utilized and a few new transformer protection schemes are constructed based on equivalent instantaneous leakage inductance and generalized instantaneous power. These schemes can efficiently solve the problems of lack of sensitivity when no&#x2010;load switching at faults and malfunction in the case of TA saturation due to external fault. With regard to transformer protection, the demand for high reliability and rapid response are on the increase, with larger capacity transformers constantly being brought into operation. The chapter further introduces a new location method for multiple inter&#x2010;line and grounded faults of double&#x2010;circuit transmission lines based on compensation voltage.</description><edition>1</edition><identifier>ISBN: 9781119304807</identifier><identifier>ISBN: 1119304806</identifier><identifier>EISBN: 9781119304814</identifier><identifier>EISBN: 1119304822</identifier><identifier>EISBN: 9781119304821</identifier><identifier>EISBN: 1119304814</identifier><identifier>EISBN: 9781119304838</identifier><identifier>EISBN: 1119304830</identifier><identifier>DOI: 10.1002/9781119304814.ch2</identifier><identifier>OCLC: 1030816578</identifier><identifier>LCCallNum: TK3105 .M3 2017</identifier><language>eng</language><publisher>Singapore: Wiley</publisher><subject>current information ; double‐circuit transmission lines ; local area conventional protection ; TA saturation ; transformer protection ; transmission line protection ; voltage information</subject><ispartof>Hierarchical Protection for Smart Grids, 2018, p.17-173</ispartof><rights>2017 John Wiley & Sons</rights><rights>2018 Science Press</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://ebookcentral.proquest.com/covers/5333085-l.jpg</thumbnail><link.rule.ids>779,780,784,793,27925</link.rule.ids></links><search><contributor>Ma, Jing</contributor><contributor>Wang, Zengping</contributor><creatorcontrib>Ma, Jing</creatorcontrib><creatorcontrib>Wang, Zengping</creatorcontrib><title>Local Area Conventional Protection</title><title>Hierarchical Protection for Smart Grids</title><description>Higher demand is putting stress on the reliability, rapidity and sensitivity of local area conventional protection. This chapter introduces an improved scheme for transformer differential protection and new protection schemes different from differential protection. In the chapter, voltage and current information are comprehensively utilized and a few new transformer protection schemes are constructed based on equivalent instantaneous leakage inductance and generalized instantaneous power. These schemes can efficiently solve the problems of lack of sensitivity when no&#x2010;load switching at faults and malfunction in the case of TA saturation due to external fault. With regard to transformer protection, the demand for high reliability and rapid response are on the increase, with larger capacity transformers constantly being brought into operation. The chapter further introduces a new location method for multiple inter&#x2010;line and grounded faults of double&#x2010;circuit transmission lines based on compensation voltage.</description><subject>current information</subject><subject>double‐circuit transmission lines</subject><subject>local area conventional protection</subject><subject>TA saturation</subject><subject>transformer protection</subject><subject>transmission line protection</subject><subject>voltage information</subject><isbn>9781119304807</isbn><isbn>1119304806</isbn><isbn>9781119304814</isbn><isbn>1119304822</isbn><isbn>9781119304821</isbn><isbn>1119304814</isbn><isbn>9781119304838</isbn><isbn>1119304830</isbn><fulltext>true</fulltext><rsrctype>book_chapter</rsrctype><creationdate>2018</creationdate><recordtype>book_chapter</recordtype><recordid>eNpVkEFLxDAQhSOiqGt_wN4W77vOZJo2OS5FV2FBD3oOSZiyxdKsbVX892aplx6Gxxv45vFGiCXCBgHkvSk1IhqCXGO-CQd5JrLZ7nzmobwUNwgEGgtV6iuRDUPjgVDnipS5Fnf7GFy72vbsVlXsvrkbm9ilzWsfRw4ncysuatcOnP3rQrw_PrxVT-v9y-652u7XTQqQaywK56gsVM3SgIfaldIBkYbcKA4-BDK-JoVJgvahpuS8coUxRoZQ0ELgdPenafnXso_xY7AI9lTczkraVPw0iZETc-zj5xcP44SFVKN3bTi448j9YBVReoGyUltSCVpOUMPMdorROQLmRH_URGFx</recordid><startdate>2018</startdate><enddate>2018</enddate><creator>Ma, Jing</creator><creator>Wang, Zengping</creator><general>Wiley</general><general>John Wiley & Sons, Incorporated</general><general>John Wiley & Sons Singapore Pte. Ltd</general><scope>FFUUA</scope></search><sort><creationdate>2018</creationdate><title>Local Area Conventional Protection</title><author>Ma, Jing ; Wang, Zengping</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i1032-166aa3765fe290b0fa72a03380495ecbcc39bf35139bc8bcf3bf3b5a69992cc63</frbrgroupid><rsrctype>book_chapters</rsrctype><prefilter>book_chapters</prefilter><language>eng</language><creationdate>2018</creationdate><topic>current information</topic><topic>double‐circuit transmission lines</topic><topic>local area conventional protection</topic><topic>TA saturation</topic><topic>transformer protection</topic><topic>transmission line protection</topic><topic>voltage information</topic><toplevel>online_resources</toplevel><creatorcontrib>Ma, Jing</creatorcontrib><creatorcontrib>Wang, Zengping</creatorcontrib><collection>ProQuest Ebook Central - Book Chapters - Demo use only</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ma, Jing</au><au>Wang, Zengping</au><au>Ma, Jing</au><au>Wang, Zengping</au><format>book</format><genre>bookitem</genre><ristype>CHAP</ristype><atitle>Local Area Conventional Protection</atitle><btitle>Hierarchical Protection for Smart Grids</btitle><date>2018</date><risdate>2018</risdate><spage>17</spage><epage>173</epage><pages>17-173</pages><isbn>9781119304807</isbn><isbn>1119304806</isbn><eisbn>9781119304814</eisbn><eisbn>1119304822</eisbn><eisbn>9781119304821</eisbn><eisbn>1119304814</eisbn><eisbn>9781119304838</eisbn><eisbn>1119304830</eisbn><abstract>Higher demand is putting stress on the reliability, rapidity and sensitivity of local area conventional protection. This chapter introduces an improved scheme for transformer differential protection and new protection schemes different from differential protection. In the chapter, voltage and current information are comprehensively utilized and a few new transformer protection schemes are constructed based on equivalent instantaneous leakage inductance and generalized instantaneous power. These schemes can efficiently solve the problems of lack of sensitivity when no&#x2010;load switching at faults and malfunction in the case of TA saturation due to external fault. With regard to transformer protection, the demand for high reliability and rapid response are on the increase, with larger capacity transformers constantly being brought into operation. The chapter further introduces a new location method for multiple inter&#x2010;line and grounded faults of double&#x2010;circuit transmission lines based on compensation voltage.</abstract><cop>Singapore</cop><pub>Wiley</pub><doi>10.1002/9781119304814.ch2</doi><oclcid>1030816578</oclcid><tpages>157</tpages><edition>1</edition></addata></record> |
fulltext | fulltext |
identifier | ISBN: 9781119304807 |
ispartof | Hierarchical Protection for Smart Grids, 2018, p.17-173 |
issn | |
language | eng |
recordid | cdi_wiley_ebooks_10_1002_9781119304814_ch2_ch2 |
source | Alma/SFX Local Collection |
subjects | current information double‐circuit transmission lines local area conventional protection TA saturation transformer protection transmission line protection voltage information |
title | Local Area Conventional Protection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T18%3A40%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=bookitem&rft.atitle=Local%20Area%20Conventional%20Protection&rft.btitle=Hierarchical%20Protection%20for%20Smart%20Grids&rft.au=Ma,%20Jing&rft.date=2018&rft.spage=17&rft.epage=173&rft.pages=17-173&rft.isbn=9781119304807&rft.isbn_list=1119304806&rft_id=info:doi/10.1002/9781119304814.ch2&rft_dat=%3Cproquest_wiley%3EEBC5333085_28_35%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781119304814&rft.eisbn_list=1119304822&rft.eisbn_list=9781119304821&rft.eisbn_list=1119304814&rft.eisbn_list=9781119304838&rft.eisbn_list=1119304830&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=EBC5333085_28_35&rft_id=info:pmid/&rft_ieee_id=8410143&rfr_iscdi=true |